Initial Installation
QUALIFIED INSTALLERS ONLY
D
iRect
v
ent
:
WARNING: This appliance has been designed to draw room air for proper heat circulation
from the bottom of the unit, and out the top front. Blocking or modifying these openings in
any way can create hazardous situations.
The vent length for the Q1GI must be between 7” (18 cm) and 44ft (13.4 m). This model is vented
with co-axial 4” intake, 6 5/8” exhaust aluminum or stainless steel approved rigid vent leading into a
vertical or horizontal termination cap. The flue collar of this model will fit inside of a standard 4” x 6
5/8” vent and must be either correctly interlocked or fastened, with three screws directly to the vent.
The Q1GI may also be converted to a fireplace insert with the use of a co-linear vent adapter kit (50-
2982) see
I
nItIal
I
nstallatIon
- c
o
-l
Inear
V
entIng
a
daPter
K
It
. When converted to co-linear venting
the lenth of vent must be between 8’ (2.44m) and 40’ (12.19m). The insert model is vented with
a 3” intake and a 3” exhaust aluminum or stainless steel approved flex vent leading into a vertical
termination cap only. The flue collars of this model will fit inside of a standard 3” vent
and must be fastened directly to the vent with three screws. The exhaust vent and air intake are both
located on the top of the unit.
Check periodically that the vents are unrestricted. Also ensure that all direct vent pipes have been
properly sealed and installed after routine inspection or cleaning. The air intake and exhaust pipes must
be installed in the correct locations on the top of the Q1GI.
v
enting
f
iRepLace
i
nseRts
:
When using the co-linear venting adapter kit (50-2982) the Q1GI may be installed and vented into any
solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local
building codes and has been constructed of noncombustible materials. Please reference the information
in Table 8 and Figures 38. An approved chimney liner and rain cap must be used. A throat connector or
flashing must be installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow
the manufacturer’s instructions that accompany the chimney liner kit. Use double walled aluminum
flex vent (3” flex conversion piece and 4”x 6 5/8” cap) from the following approved products; Simpson
Dura-Vent (Direct Vent GS). If necessary, remove the vent collar plate from the top of the insert and
connect it securely to the liner with sheet metal screws. Check for any tears in the liner at this point.
IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed.
NOTE:
If the Q1GI unit is pulled out of its installation, and the vent-air intake system is disconnected
for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant and
reconnected with three (3) sheet metal screws evenly spaced.