Installation
S
lider
/d
amper
S
et
-u
p
:
This is used to regulate the airflow through the pellet stove.
Figure 15: Slider/Damper Plate & Rod in Unit.
This unit is designed to operate within a negative pressure range of
0.15-0.17 inches of water column (37-42
Pa).
This can be measured using a Magnahelic pressure gauge once the unit has been running on heat level 5
setting after one hour of burn time. This adjustment is necessary for varying venting configurations. The reading
can be taken from the ⅛” hole located above the top right corner of the door. A #8 screw must be removed in
order to access this hole.
The Combustion Trim, Feed Trim and Fuel Type Functions can be used to compensate for varying fuel qualities.
Refer to page 7 in the Owners Manual for circuit board operation.
If, after long periods of burning, the fire builds up or there is a build up of clinkers, this would be a sign that the
fuel quality is poor - this requires more air.
The easiest way to make sure that an efficient flame is achieved is to understand the characteristics of the fire.
• A tall, lazy flame with dark orange tips requires more air.
• A short, brisk flame, like a blowtorch, has too much air .
• If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame with no black
tips then the air is set for proper operation, refer to Figure 16.
SPECIAL NOTES:
Fuel quality is a major factor in how the stove will operate. If the fuel has a high moisture content or ash content
the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-
up).
Figure 16: Efficient Flame.
NOTE: THE SURROUND
PANEL MOUNT WAS
REMOVED FOR CLARITY
CONVECTION
FAN
SLIDER
DAMPER
EXHAUST
CHANNEL
EXHAUST SENSOR &
REMOVABLE PLATE
19