Initial Installation
QUALIFIED INSTALLERS ONLY
b V
ent
m
oDeL
:
WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the
room. It is also designed to draw room air for proper heat circulation from the sides of the unit. Blocking or
modifying the louvers in any way can create hazardous situations, either through poor venting or by overheating.
It is important that this unit has sufficient air circulation for proper venting and combustion. Provisions must
be made for the supply of adequate combustion and ventilation air. These openings must not be blocked. The
appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.
c
onVeRting
a D
iRect
V
ent
F
iRepLace
t
o
a b-V
enteD
F
iRepLace
:
spaced to new 4’’ chimney connector.
5. Test fire the appliance and ensure proper operation. A venturi adjustment could be required to achieve
an efficient flame. Improper operation or adjustment could result in Carbon Monoxide production causing
personal injury or property damage.
c
onVeRting
a b-V
ent
F
iRepLace
t
o
a D
iRect
V
enteD
F
iRepLace
:
Parts required for conversion
1 - Drafthood (2 - 3’’ dual pipe chimney connector), 2 - Air channel cover plates, 1 - Drafthood cover plate.
1. Remove the chimney connector, 300° spill switch, two (2) B-vent air channels and B-vent draft diverter plate.
Chimney
Connector
Drafthood
Diverter
300°F (140°F)
Spill Switch
Air Channels (x2)
Parts required for conversion
1 - 300°F (149°C) manual reset spill switch and wires
1 - Drafthood (4’’ chimney connection)
2 - Air channels
1 - Drafthood diverter
1.
Remove the chimney connector, fresh air cover
plates and draft hood cover plate.
2.
Install the 300°F (149°C) spill switch in the location
provided.
3.
Install the two fresh air channels in the correct
locations.
4. Install a new 4’’ chimney liner into the existing and
attach with three (3) sheet metal screws evenly
Figure 19: Converting To A BV Fireplace.
2.
Install the two (2) air channel cover plates in the
locations provided.
3.
Install the draft hood cover plate in the location
provided.
4. Install two (2) 3’’ chimney liners in the existing
chimney, securing the 3’’ liners with three (3) sheet
metal screws evenly spaced to the new chimney
connector.
5. Test fire the appliance and ensure proper operation.
A venturi adjustment could be required to achieve
an efficient flame. Improper operation or adjustment
could result in Carbon Monoxide production causing
personal or property damage.