Enviro EG-40 Owner'S Manual Download Page 23

 

23

PARTS LIST 

 

EC-001 

120 

°

 F (49 

°

C) Ceramic Temperature Sensor 

EG40-086  

Freestanding Side Panel 

EC-002 

220 

°

F (104 

°

C) Ceramic Spill Switch 

EG40-087  

BV Stove Top 

EC-006 

S.I.T. NOVA Valve NG 

EG40-087A  

DV Stove Top 

EC-007 

S.I.T. NOVA Valve LP 

EG40-088 

Firebox Baffle  

EC-009 

Thermocouple Post (10/00) EG40-089 

Front 

Burner 

EC-011 

Spark Electrode with Ignitor Wire 

EG40-091 

Stove Top Baffle BV 

EC-012  

Thermopile 

EG40-091A 

Stove Top Baffle DV 

EC-013 

Pilot NG with electrode EG40-098 

Front 

Venturi 

EC-014 

Pilot LP with electrode 

EG40-099 

Rear Venturi 

EC-015 

Fully Assembled Pilot NG 

EG40-120 

Freestanding Burner Gasket 

EC-016  

Fully Assembled Pilot LP 

EG40-123 

Window Channel Tape 72” 

EC-019 

Pilot Orifice (Injector) NG Threaded 

EG40-129 

Steel Brick Liner 

EC-020 

Pilot Orifice (Injector) LP Threaded EG40-135 

Freestanding Pedestal Door 

EC-021 

Pilot Gasket 

EG40-200 

LP to NG Conversion Kit 

EC-023 

S.I.T. Piezo Ignitor 

EG40-202 

NG to LP Conversion Kit 

EC-024 

S.S. Flex Connector with 3/8” Elbow 18” Long 

EG40-213  

Freestanding Ash Sill (post 3/00) 

EC-025 

Freestanding Burner Switch 

EG40-302 

Door Latch Strip Hinge (Set of 2) 

EC-031 

Miniature Light Bulb (115V) 

EG40-304 

Freestanding Fan Mount 

EC-032  

Light Bulb Holder 

EG40-307 

Freestanding Pedestal Box Cover 

EC-037 

Freestanding Wiring Harness Complete  
(2 pieces) 

30-014 

Freestanding Burner Control NG 
Complete 

EC-040 

Freestanding Fan Control Knob 

30-015 

Freestanding Burner Control LP Complete 

EC-043 

IEC Power Cord 

30-017 

Rear Burner (Post 2000) 

EC-045 

Embers 

30-040 

EG 40 Right Log 

EC-053 

Tapped Corner Bracket 

30-041 

EG 40 Left Log 

EC-054 

1 X 1 Side Cabinet Hinge 

30-042 

EG 40 Rear Log 

EC-056 

Freestanding Pedestal Door Magnet  

30-043 

Pilot Line with Brass Ferals 

EC-057 

3/8” Tadpole Door Gasket (6.9ft) 

50-081  

EG 40 Log Set Complete 

EC-058 

Window Channel Tape 

50-343 

Blank Orifice – Front 

EC-059 

Door Latch Bolt 

50-345 

Freestanding Pilot Tubing and Fittings 

EC-060 

Simpson Duravent GS Adapter 

50-478 

Freestanding Bar Set - Nickel 

EC-066 

Freestanding Light Switch 

EG40-115 

Freestanding Bar Set - Gold 

EC-067 

Vent Restrictor Ring 

50-480 

Outer Door Cover (A) - Gold 

EF-045 

Freestanding Fan Controller 

50-481 

Outer Door Cover (A) - Nickel 

EG40-023 

Latch Bracket & Nut 

50-776 

Outer Door Cover (A) - Painted 

EG40-033 

Convection Air Deflectors 

50-514 

Convection Blower 

EG40-049 

Freestanding Side Panel Magnets 

50-652 

16” Ignitor Cable 

EG40-066 

Fan Access Cover Gasket 

50-713 

IEC Power Cord Outlet 

EG40-070 

Freestanding DV Owner’s Manual 

50-774 

Burner Tray Top Freestanding NG  
(Post 2000) 

EG40-071 

Freestanding BV Owner’s Manual 

50-775 

Burner Tray Top Freestanding LP  
(Post 2000) 

EG40-077 

Complete Inner Door with glass 

 

 

EG40-078 

Beveled Panel - 40” x 28” 

 

 

EG40-079 

O/S Beveled Panel - 46” x 33” 

 

 

EG40-080 Freestanding 

Pedestal 

 

 

Summary of Contents for EG-40

Page 1: ...on may result causing property damage personal injury or loss of life installation and service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasolin...

Page 2: ...tallation must conform to local codes or in the absence of local codes with the current CAN1 B 149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent i...

Page 3: ...IGH ALTITUDE SPECS ENVIRO EG 40 DIRECT VENT UNITS Have all been certified for use with either natural or propane gases See control panel and rating label Are not for use with solid fuels Must not be c...

Page 4: ...aintenance Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building E g cutting a wall or ceiling joist The stove can be installed...

Page 5: ...inimum K Clearance to a mechanical air supply inlet 6 feet 1 8m minimum L Clearance above paved side walk or paved driveway located on public property 7 feet 2 1m minimum M Clearance under verandah po...

Page 6: ...PERMITTED TO REACH THE OUTSIDE VENT TERMINATION BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED FOLLOW THE VENT LENG...

Page 7: ...dentations located on the female end of the pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match an...

Page 8: ...nts excessive heat from possibly melting the vinyl siding material Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff Shaded area in FIG 12 so that an a...

Page 9: ...pipe and elbows may be utilized in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to the higher corrosion resistance STEP 6 Once the pipe sections h...

Page 10: ...t the second floor and any subsequent floors FIG 19 The opening should be framed to 10 inch x 10 inch inside dimensions in the same manner as shown in FIG 16 2 Any occupied areas above the first floor...

Page 11: ...ide on a location for the unit that will meet any or all local code requirements Refer to sections in this manual Deciding Were To Locate Your Stove and Planning Your Installation Set the appliance in...

Page 12: ...liner over collar secure the flex liner with 3 sheet metal screws evenly spaced Align all straight sections of pipe slipping all joints together and installing 3 sheet metal screws evenly spaced A sm...

Page 13: ...nimum 4 flex liner to the top of the CLASS A chimney Placing a bead of high temperature silicone to the Simpson Cap adapter and securely attach the flex liner to the adapter Secure the cap adapter to...

Page 14: ...t is very important to install these logs in their correct position to insure safe optimum operating conditions Open the door of the fireplace Place the logs on the log supports Close the door and tig...

Page 15: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Page 16: ...first 4 hours of use See page 14 After that depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a so...

Page 17: ...d Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile if low see Pilot will...

Page 18: ...the current edition of the National Fuel Gas Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON WARNOCK HERSEY RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pres...

Page 19: ...ly to the floor WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly gr...

Page 20: ...Voltage Thermostat REMOVING THE BLOWER 20 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burne...

Page 21: ...lot orifice First remove the two 2 T 20 Torx screws that hold the pilot assembly to the burner tray Lift the pilot assembly from the burner tray Using a 10mm wrench disconnect the pilot line from the...

Page 22: ...ts only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under t...

Page 23: ...g Harness Complete 2 pieces 30 014 Freestanding Burner Control NG Complete EC 040 Freestanding Fan Control Knob 30 015 Freestanding Burner Control LP Complete EC 043 IEC Power Cord 30 017 Rear Burner...

Page 24: ...r 2003 EG40 GAS TRAY AND DOOR ASSEMBLIES Rear Venturi EG40 099 S I T Nova 820 Valve EC 006 NG EC 007 LPG S I T Piezo Ignitor EC 023 Burner Switch EC 025 Light Switch EC 066 FS Fan Controller EF 045 FS...

Page 25: ...ing Side Panel Cabinet EG40 086 Flue Pipe Freestanding Pedestal Wiring Plate Freestanding Pedestal Box Cover EG40 307 1x1 Side Cabinet Hinge EC 054 Freestanding Side Panel Cabinet EG40 086 Convection...

Page 26: ..._________ Name of Installer ___________________________________________ Address _______________________________________ ___________________________________________ ____________________________________...

Reviews: