PARTS AND ACCESSORIES
Service Parts available from your local Enviro Dealer
Burner Control Assembly
Natural Gas Pilot Assembly
Propane Pilot Assembly
Door Bolt
Relief Door Gasket
Regulating Valve
Piezo Ignitor
Burner Switch
B-vent Spill switch 220
°
Orifice Blank
Convection Blower
Light Bulb Holder
Light Switch (momentary)
Fan Controller
Log Set (with Embers)
Thermocouple
Embers
Thermopile
Door Gasket
Convection Fan Sensor 120 F (49C)
Accessories
Gold trim Package
Low Voltage Thermostat
REMOVING THE BLOWER
20
1. Turn the unit off and remove the log set.
2. Remove the burner tray assembly by
removing the screw on either side of the
tray, between the front and rear burners.
Lift the tray out. Remove the brick liner by
undoing the screw on either side and
sliding the panel out.
3. Remove the 4-5/16” bolts that hold the
blower mounting plate to the back firewall.
Use a light lubricating oil on screws before
removal.
4. Carefully pull the blower assembly into the
firebox disconnect the blower leads from
the harness and remove blower.
5. To re-install, check mounting plate gasket if
damaged replace with new one and reverse
steps 1 through 4.