29
Horizontal
Vent Shield
Initial Installation
QUALIFIED INSTALLERS ONLY
[54] 2 1/8"
[520] 20 1/2"
[418] 15 1/2"
Figure 39:
Dimensions for a Horizontal Installation
[54] 2 1/8"
[520] 20 1/2"
[418] 15 1/2"
[244] 9 5/8"
[275] 10 7/8"
Figure 40:
Dimensions for a Vertical Installation
h
oRizontaL
V
ent
instaLL
:
Figure 39 shows a horizontal vent installation with minimum clearances. The horizontal vent shield must
be used when the minimum vent configuration is used. If more than 12” of vertical rise is used the shield
should not be installed. The vent to ceiling clearance must be maintained no matter the additional vertical
vent height; see Figure 35 & Figure 36. A minimum of 1” clearance on all sides of the vent pipe must be
maintained at all time unless specifically stated.
V
eRticaL
V
ent
instaLL
:
Figure 40 shows a vertical vent installation with minimum install clearances. Vertical vent shield is needed,
the horizontal vent shield is not required for vertical vent configurations. A minimum of 1” clearance on all
sides of the vertical vent pipe must be maintained at all time unless specifically stated. Please see Initial
Installation - Vertical Termination for further details.
Summary of Contents for C44I
Page 55: ...55 Parts Diagram 13 14 6 11 5 3 10 1 2 12 12 9 7 8 11 9 8 13 4 7 10 15 ...
Page 57: ...57 Notes ...
Page 58: ...58 Notes ...