46
The C44I / C44ID needs a hardwired power connection in order for the unit to operate. There is also a
battery pack that takes four AA batteries in case there is a loss of power.
All electrical connections must be made by a certified electrician.
There is an electrical box located in the
cabinet on the left side of the fireplace. The
Power wire connection is to be made inside
the elctrical box. There is a strain relief on
the outside of the cabinet to secure the
wiring in place.
C44I Models: Wire incoming power to the
supplied receptacle as shown in Figure 59.
C44ID Models: Remove the steel cover plate
from the electrical box and connect incoming
power to the wires inside.
120V
Figure 59: C44I Receptacle Wiring
C44I / C44ID IPI Dual Covection Fan Kit (50-4173)
The C44I / C44ID has an optional dual convection fan kit that can be installed at before or after the
fireplace installation. The fans are operated by the remote controller. The fans can be turned on or off at
anytime with the remote. There are also 6 different fan speed settings.
The fireplace must be electrically connected and grounded in accordance with local codes or, in the
absence of local codes, with the current CSA C22.1 Canadian Electrical Code Part 1, Safety Standards For
Electrical Installations, or The National Electrical Code ANSI / NFPA 70 in the US..
CAUTION: When servicing controls, label all wires prior to disconnection. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing. If any of the original wire
supplied with the appliance must be replaced, it must be replaced with 18 AWG wire with a temperature
rating of 105°C.
Initial Installation
QUALIFIED INSTALLERS ONLY