CLEANING & MAINTENANCE

Keep the Therapure

®

240 functioning properly by cleaning the Cleanable HEPA-Type filter every four 

weeks of use. More frequent cleaning will be necessary if the unit is located in an area with a high level 

of airborne contaminants (excessive amounts of smoke, pet dander, etc.).

Exposing the Therapure

®

 240 to candle/oil/fireplace soot and smoke is not recommended and will 

require more frequent cleaning. 

Note: Always make sure the Therapure

®

 240 is turned off and unplugged before cleaning.   

»  Vacuuming will restore performance of the Cleanable HEPA-Type Filter. However,  

  the filter may appear stained. This is normal and does not affect performance in any way.
»  Do not use water or any household cleaners or detergents to clean the Cleanable  

  HEPA-Type Filter.
»  The inlet grill may be cleaned (after unit is turned off and unplugged) with a vacuum  

  or a slightly damp cloth.

 

Cleaning the Cleanable HEPA-Type Filter

1.  Release the inlet grill by pressing on the locking latch (see diagram of Main Parts).

2.  Remove the inlet grill from the unit as shown below.

3.  Grasp the left and right frames of the Cleanable HEPA-Type Filter through the indentations on  

 

the sides of the filter enclosure and remove the filter.

4.  To clean the Cleanable HEPA-Type Filter, use the brush or crevice attachment with a vacuum    

 

cleaner. Run the attachment along the inlet and outlet side of the filter, cleaning between the    

 

crevices as much as possible. 

Do not use water or any household cleaners or detergents  

 

to clean the Cleanable HEPA-Type Filter.

5.  Once the Cleanable HEPA-Type Filter has been cleaned and checked for any possible damage, 

replace the filter back in the reverse direction described here. Plug in the unit and 

hold down  

Time + Power On button for 3 seconds

. The clean filter light will go off and your cleaning 

maintenance is done.

1.

2.

4.

3.

OPERATING THE THERAPURE

®

 240

Controls/Settings
Power Control –

 To operate the Therapure

®

 240 air purifier,press the “ON/OFF” button to turn  

on the air purifier, press the button again to turn off the air purifier.

Timer Control –

 The Therapure

®

 240 air purifier can be programmed to turn off after a preset amount 

of time. Press the “TIMER” button to program the timer. Each press will add one hour up to a total of 

24 hours. Keeping the button pressed will automatically increase to 24 hours, 1 hour at a time, after 

that it will turn back to off.

ION Generator –

 Press the ION Generator button to turn on the ions. Press it again to turn  

off the ions.

Speed Control –

 The Therapure

®

 240 has three different speeds of cleaning, LOW, MED and HI.  

Press “SPEED” button to cycle the settings and select the fan speed you desire. The speed state  

will be shown on the LED display.

UV Control –

 Press the UV/VOC control button “UV/VOC” to turn on the UV lamp.  

Press it again to turn off the UV and VOC.

Clean Filter Indicator Light –

 The Therapure

®

 Clean Filter Indicator Light will turn on each time  

the filter needs to be cleaned.

Reset Filter Control –

 Press down the “TIMER” and “ON/OFF” button for 3 seconds, the clean filter 

light will flash 3 times and then the clean filter light will turn off, indicating the unit has  

been reset.   

LED Display

ION Button

Timer Button

Clean Filter  

Indicator Light

Speed Button

Power Button

UV/VOC Button

Summary of Contents for thera pure TPP240

Page 1: ...UV AIR PURIFIER MANUAL TPP240 UV AIR PURIFIER 50089 01 USCA SKU 50108 MANUAL TPP240...

Page 2: ...TPP240 TPP240 3 2 INSTRUCTIONS FOR USE 4 MODE D EMPLOI 20...

Page 3: ...and upgrades Please be sure to read the following instructions carefully to ensure optimal performance and safety envionproducts com Therapure by BONECO North America Corp P O Box 9159 Van Nuys CA 914...

Page 4: ...ift the Therapure 240 air purifier Do not pull the cord against or around sharp corners and edges This could result in injury to the user or damage to the cord Always remove the plug from its power ou...

Page 5: ...speed settings low medium and high 8 Power Button 9 Timer Button 10 LED Display 11 UV Indicator Light Bar Lights up when UV feature is turned ON 12 Clean Filter Indicator Lights up when it s time to...

Page 6: ...NS and IMPORTANT WARNINGS sections of this manual Position your Therapure at least one foot 12 inches from the wall Plug in the unit OPERATING THE THERAPURE 240 Safety 1 Do not place near fans 2 Keep...

Page 7: ...anable HEPA Type Filter 5 Once the Cleanable HEPA Type Filter has been cleaned and checked for any possible damage replace the filter back in the reverse direction described here Plug in the unit and...

Page 8: ...se the effectiveness of the lamp Never operate the unit without a filter or with a damaged filter UV lamp cover must be installed at all times The UV light from the UV lamp will result in severe damag...

Page 9: ...PERIOD Some states do not allow limitations on the duration of implied warranties so the above limitation may not apply to you While this warranty gives you specific legal rights you may also have oth...

Page 10: ...3 ARBITRATION PROCEDURES a Before instituting an arbitration if you have any dispute we strongly encourage you to contact the Company to try to resolve the matter by calling 800 875 8577 although you...

Page 11: ...ire attentivement les consignes suivantes pour garantir une performance et une s curit optimales envionproducts com TherapureMD by BONECO North America Corp P O Box 9159 Van Nuys CA 91409 8291 800 875...

Page 12: ...er tra ner tirer ou soulever le purificateur d air TherapureMD 240 Ne tirez pas le cordon contre ou pr s de coins ou de rebords tranchants L utilisateur pourrait se blesser ou le cordon tre endommag D...

Page 13: ...es de vitesse de ventilation low medium et high 8 Bouton d alimentation 9 Bouton de la minuterie 10 Affichage DEL 11 Indicateur lumineux UV s allume quand la caract ristique UV est ON 12 Indicateur de...

Page 14: ...S DE S CURIT et AVERTISSEMENTS IMPORTANTS du pr sent manuel Placez votre TherapureMD au moins un pied 12 pouces du mur Branchez l appareil FAIRE FONCTIONNER LE THERAPUREMD TPP100 S curit 1 Ne le place...

Page 15: ...toyable 5 Apr s avoir nettoy le filtre de type HEPA nettoyable et v rifi qu il n est pas endommag replacez le filtre dans la direction inverse d crite ici Branchez l appareil et enfoncez le bouton Tim...

Page 16: ...ts diminuera l efficacit de la lampe Ne faites jamais fonctionner l appareil sans filtre ou avec un filtre endommag Le couvercle de la lampe UV doit tre install en tout temps La lumi re UV peut causer...

Page 17: ...i au vendredi de 7 h 16 h HNP ou le samedi de 7 h 15 h Cette garantie ne couvre pas des dommages caus s par accident une mauvaise utilisation ou toute utilisation autre que celle pr vue et d crite dan...

Page 18: ...ollectif ni action de repr sentation de quelque autre type ne soit permise 3 PROC DURES D ARBITRAGE a Avant d instituer une proc dure d arbitrage si vous avez un diff rend nous vous encourageons forte...

Reviews: