TPP240
TPP240
13
12
CLEANING & MAINTENANCE
Keep the Therapure
®
240 functioning properly by cleaning the Cleanable HEPA-Type filter every four
weeks of use. More frequent cleaning will be necessary if the unit is located in an area with a high level
of airborne contaminants (excessive amounts of smoke, pet dander, etc.).
Exposing the Therapure
®
240 to candle/oil/fireplace soot and smoke is not recommended and will
require more frequent cleaning.
Note: Always make sure the Therapure
®
240 is turned off and unplugged before cleaning.
» Vacuuming will restore performance of the Cleanable HEPA-Type Filter. However,
the filter may appear stained. This is normal and does not affect performance in any way.
» Do not use water or any household cleaners or detergents to clean the Cleanable
HEPA-Type Filter.
» The inlet grill may be cleaned (after unit is turned off and unplugged) with a vacuum
or a slightly damp cloth.
Cleaning the Cleanable HEPA-Type Filter
1. Release the inlet grill by pressing on the locking latch (see diagram of Main Parts).
2. Remove the inlet grill from the unit as shown below.
3. Grasp the left and right frames of the Cleanable HEPA-Type Filter through the indentations on
the sides of the filter enclosure and remove the filter.
4. To clean the Cleanable HEPA-Type Filter, use the brush or crevice attachment with a vacuum
cleaner. Run the attachment along the inlet and outlet side of the filter, cleaning between the
crevices as much as possible.
Do not use water or any household cleaners or detergents
to clean the Cleanable HEPA-Type Filter.
5. Once the Cleanable HEPA-Type Filter has been cleaned and checked for any possible damage,
replace the filter back in the reverse direction described here. Plug in the unit and
hold down
Time + Power On button for 3 seconds
. The clean filter light will go off and your cleaning
maintenance is done.
1.
2.
4.
3.
OPERATING THE THERAPURE
®
240
Controls/Settings
Power Control –
To operate the Therapure
®
240 air purifier,press the “ON/OFF” button to turn
on the air purifier, press the button again to turn off the air purifier.
Timer Control –
The Therapure
®
240 air purifier can be programmed to turn off after a preset amount
of time. Press the “TIMER” button to program the timer. Each press will add one hour up to a total of
24 hours. Keeping the button pressed will automatically increase to 24 hours, 1 hour at a time, after
that it will turn back to off.
ION Generator –
Press the ION Generator button to turn on the ions. Press it again to turn
off the ions.
Speed Control –
The Therapure
®
240 has three different speeds of cleaning, LOW, MED and HI.
Press “SPEED” button to cycle the settings and select the fan speed you desire. The speed state
will be shown on the LED display.
UV Control –
Press the UV/VOC control button “UV/VOC” to turn on the UV lamp.
Press it again to turn off the UV and VOC.
Clean Filter Indicator Light –
The Therapure
®
Clean Filter Indicator Light will turn on each time
the filter needs to be cleaned.
Reset Filter Control –
Press down the “TIMER” and “ON/OFF” button for 3 seconds, the clean filter
light will flash 3 times and then the clean filter light will turn off, indicating the unit has
been reset.
LED Display
ION Button
Timer Button
Clean Filter
Indicator Light
Speed Button
Power Button
UV/VOC Button