Shenzhen Envicool Technology Co., Ltd.
Note: For the nameplate parameters on the air
conditioner, the user are advised to read them
carefully, In the actual use of the technical
parameters, the nameplate nominal parameters
shall prevail.
1.3 Standards
Standard
Description
GB/T
17626.7-1998
EMC
GB4706.1
Safety of household
appliances or similar electric
appliance
GB4798.1
Environmental conditions
existing in the application of
electric and electronic
product – Storage
GB4798.2
Environmental conditions
existing in the application of
electric and electronic
product – Transportation
GB4798.3
Environmental conditions
existing in the application of
electric and electronic
product – Use
2. Safety notices
The following safety notices are to be observed in
their entirety for the correct use of the equipment:
2.1 Transport
Transport the air conditioner only in condition
of usage.
Prior to transport remove the air conditioner
and pack it separately if the move the air
conditioner and pack it separately if the
complete switch cabinet is to be transported.
Failure to observe these instructions will
render the warranty provisions null and void.
When carrying the unit, it is forbidden to lift the
plastic panel, and the panel can not be used
as the support.
2.2 Storage
Never expose air conditioners to temperatures
exc70
°
during store
Store air conditioner only in condition of usage.
Failure to observe these instructions will
render the warranty provisions null and void.
2.3 Unpacking
Prior to and during unpacking make a visual
inspection of the air conditioner to see
whether any damage has occurred during
transport. Especially pay attention to loose
parts, dents, visible loss of oil etc.
Any damage mast be reported immediately to
the forwarding agent (follow the instructions
in”Rules For Damage Claims”). Moreover, the
latest edition of the “After sales Service Letter
of Commitment”
Before disposing of packing material ensure
that it does not contain any loose components.
2.4 Installation
To prevent the enclosure with the air
conditioner fitted tipping over, it is essential
that this be bolted to the floor.
A roller door is to be used to ensure problem
free opening and closing of the enclosure
door.
The site for the enclosure, and hence the
arrangement of the air conditioner, is selected
so as to ensure good ventilation;
The location is free from excessive dirt and
moisture;
The ambient temperature does not exceed
+55
℃
;
The enclosure is sealed on all sides (IP54).
Condensation will occur if the enclosure is
leakage;
Air inlet and outlet are not obstructed on the
inside of the enclosure;
The duct size outside the air conditioner
cabinet should not be less than the limit value
in the following figure.
Units are only fitted horizontally in the
specified position. Max. Deviation from the
true horizontal:2°;
Losses from the components installed in the
enclosure must not exceed the specific
refrigeration capacity of the air conditioner
itself;
EIA series air conditioner user manual