Section 7
Electrode management
44
Force calibration
The analog input and analog output can be used for force control in terms of kN or lbf when they have
been calibrated.
Parameter
Units
Range
Description
OUT Point 1
mV
0 - 10000
Analog output (point 1)
OUT Point 1
kN/lbf
Measured output force (point 1)
OUT Point 2
mV
0 - 10000
Analog output (point 2)
OUT Point 2
kN/lbf
Measured output force (point 2)
IN Point 1
mV
0 - 10000
Analog input (point 1)
IN Point 1
kN/lbf
Measured input force (point 1)
IN Point 2
mV
0 - 10000
Analog input (point 2)
IN Point 2
kN/lbf
Measured input force (point 2)
The relationship between the analog input and output and the electrode force can be determined by
measuring the values at two points. The values define a linear relationship between mV and kN/lbf.
The force can be calibrated for each electrode.