30
IP2045EN - 2014-09-22
Output
Value - Accessories
Description
0 1
+
-
24 V 0,5 A
Accessories power supply.
Power supply output for external accessories, including automa-
tion status lamps.
AUX
SOFA1-SOFA2
GOPAV
The control panel has one space for coupling board, type radio
receivers, magnetic loops etc.
The coupling board working mode is selected by DIP1.
WARNING: the plug-in cards must be inserted and removed with the
power supply disconnected.
11 ... 1
24 V 3 W
Automation open lamp.
Only with the limit switch 0-11 (N.C.) connected and DIP2=OFF will
the light switch off when the automation is closed.
Automation closed lamp.
With DIP2=ON, the light switches off when the automation is open.
QIKLUX
24 V 120 mA max
Light kit for QIK barrier.
With DIP2=ON, the light switches off when the automation is open.
12 ... 1
24 V 3 W
Automation closed lamp.
Only with the limit switch 0-12 (N.C.) connected and DIP2=OFF will
the light switch off when the automation is open.
Automation open lamp.
With DIP2=ON, the light switches off when the automation is closed.
QIKLUX
24 V 120 mA max
Light kit for QIK barrier.
With DIP2=OFF, the light switches off when the automation is open.
M1
U
V
W
230 V~ 5 A
120 V (E1AJ)
Motor 1 (M1).
Terminal W must be connected to the common motor phase connec-
tion. The condenser must be connected between the U and V phases.
N W ...
LAMP
230 V~ 25 W
120 V~ (E1AJ)
Flashing light.
Activated during opening and closing operations.
C
N
...
LUXK7
230 V~ 60 W
120 V~ (E1AJ)
Courtesy light in CROSS sliding automation.
Comes on for 180 seconds after receiving any opening (total or
partial) or closing command.
230 V~ 100 W
120 V~ (E1AJ)
Drive unit external courtesy light. Comes on for 180 seconds after
receiving any opening (total or partial) or closing command.
J12
Membrane push-button panel (PT3). Starts the opening operation.
NOTE: to activate the closing operation, connect the connector of
the push-button panel to J12 (rotated by 180°).
Membrane push-button panel (PT3). Causes the blocking of the
movement.
Membrane push-button panel (PT3). Starts the closing operation.
NOTE: to activate the opening operation, connect the connector of
the push-button panel to J12 (rotated by 180°).
WARNING: use a double insulated cable
WARNING: use a double insulated cable
5. Output and accessories
Summary of Contents for Ditec E1A
Page 1: ...Ditec E1A www ditecentrematic com IP2045 ...
Page 2: ...2 IP2045 2014 09 22 Italiano 3 English 23 Français 43 Deutsch 63 Español 83 Português 103 ...
Page 4: ...4 IP2045IT 2014 09 22 ...
Page 24: ...24 IP2045EN 2014 09 22 ...
Page 44: ...44 IP2045FR 2014 09 22 ...
Page 64: ...64 IP2045DE 2014 09 22 ...
Page 84: ...84 IP2045ES 2014 09 22 ...
Page 104: ...104 IP2045PT 2014 09 22 ...
Page 123: ...123 IP2045 2014 09 22 ...