29
IP1812EN - 2016-02-05
6.8 CUBIC6FM installation
It is possible to limit the travel of the wing by means of magnetic limit switches.
Choose and install the magnetic limit switches as indicated in the relative manual.
Make the electrical connections as shown in the control panel.
WARNING: the magnetic limit switches cannot interrupt the power supply to the motor
.
7. Electrical connections
Before connecting the power supply, make sure the plate data correspond to that of the mains
power supply.
An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the
mains supply.
Check that upstream of the electrical installation there is an adequate residual current circuit
breaker and a suitable overcurrent cutout.
WARNING: the electrical connections for the extension of the motor cables must be made on the
outside of the foundation casing in an appropriate junction box (not supplied).
In the CUBIC6 gearmotors, the blue wire corresponds to the common contact of the motor phases,
and must be connected to the W or Z terminals of the control panel.
The CUBIC6 gearmotor can be connected to the E2 and LOGICM control panels.
The CUBIC6H and CUBIC6VH gearmotors can be connected to the VIVAH control panel.
The electrical connections and the start-up of the gearmotors are shown in the installation manuals
of the E2, LOGICM and VIVAH control panels.
Summary of Contents for Ditec CUBIC
Page 1: ...Ditec CUBIC www entrematic com IP1812 2016 02 05 ...
Page 2: ...2 IP1812 2016 02 05 Italiano 3 English 19 Français 35 Deutsch 51 Español 67 Português 83 ...
Page 10: ...10 IP1812IT 2016 02 05 5 Esempi di installazione max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 26: ...26 IP1812EN 2016 02 05 5 Examples applications max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 42: ...42 IP1812FR 2016 02 05 5 Exemple d application max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 58: ...58 IP1812DE 2016 02 05 5 Anwendungsbeispiel max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 74: ...74 IP1812ES 2016 02 05 5 Ejemplo de aplicacion max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 90: ...90 IP1812PT 2016 02 05 5 Exemplo de aplicação max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 99: ...99 IP1812 2016 02 05 ...