24
IP1812EN - 2016-02-05
3. Technical data
CUBIC6
CUBI6H
CUBIC6HV
Power supply
230 V~ 50 Hz
24 V
24 V
Absorption
1,5 A
12 A
12 A
Couple
340 Nm
340 Nm
220 Nm
Capacitor
10 µF
-
-
Opening time
18 s/90°
12÷25 s/90°
6÷13 s/90°
Max opening
110°-180° (see page 26)
110°-180° (see page 26)
110°-180° (see page 26)
Service class
3 - FREQUENT
4 - INTENSIVE
4 - INTENSIVE
Intermittence
S2 = 15 min
S3 = 25%
S2 = 30 min
S3 = 50%
S2 = 30 min
S3 = 50%
Temperature
min -20° C max +55° C
min -35° C max +55° C
(with NIO enabled)
min -20° C max +55° C
min -35° C max +55° C
(with NIO enabled)
min -20° C max +55° C
min -35° C max +55° C
with NIO enabled
Degree of
protection
IP67
IP67
IP67
Control panel
E2 - LOGICM
VIVAH
VIVAH
Applications
m = leaf width
kg = leaf weight
600 kg
700 kg
800 kg
500 kg
400 kg
300 kg
200 kg
100 kg
m
1
2
3
4
5
600 kg
500 kg
400 kg
300 kg
200 kg
100 kg
m
1
2
3
4
5
3.1 Operating instructions
Service class: 3
(minimum 30 cycles a day for 10 years or 60 cycles a day for 5 years).
Use: FREQUENT
(For vehicle or pedestrian accesses to town houses or small condominiums with
frequent use).
Service class: 4
(minimum 100 cycles a day for 10 years or 200 cycles a day for 5 years)
Use: INTENSIVE
(For vehicle or pedestrian accesses to large condominiums, industrial or
commercial complexes and parking lots with very frequent use).
-
Performance characteristics are to be understood as referring to the recommended weight
(approx. 2/3 of maximum permissible weight). When used with the maximum permissible
weight a reduction in the above mentioned performance can be expected.
-
Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative Having been statistically determined under average operating conditions, and are
therefore not necessarily applicable to specifi c conditions of use.
-
Each automatic entrance has variable elements such as: friction, balancing and environmental
factors, all of which may substantially alter the performance characteristics of the automatic
entrance or curtail its working life or parts thereof (including the automatic devices themsel-
ves). The installer should adopt suitable safety conditions for each particular installation.
CUBIC6L
CUBIC6LG
Summary of Contents for Ditec CUBIC
Page 1: ...Ditec CUBIC www entrematic com IP1812 2016 02 05 ...
Page 2: ...2 IP1812 2016 02 05 Italiano 3 English 19 Français 35 Deutsch 51 Español 67 Português 83 ...
Page 10: ...10 IP1812IT 2016 02 05 5 Esempi di installazione max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 26: ...26 IP1812EN 2016 02 05 5 Examples applications max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 42: ...42 IP1812FR 2016 02 05 5 Exemple d application max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 58: ...58 IP1812DE 2016 02 05 5 Anwendungsbeispiel max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 74: ...74 IP1812ES 2016 02 05 5 Ejemplo de aplicacion max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 90: ...90 IP1812PT 2016 02 05 5 Exemplo de aplicação max 110 max 180 CUBIC6L CUBIC6LG CUBIC6TC ...
Page 99: ...99 IP1812 2016 02 05 ...