© Entrematic
Group AB 2015
November 2016
6020031A — Commercial HVLS Fans
13
INSTALLATION
DOWN TUBE ASSEMBLY
1. Route the power and communication cables through the
down tube.
2. With the down tube located next to the motor assembly,
install the cable connections to the top of the motor
assembly. See Fig 8. Use the support materials contained
in the shipping package to support motor assembly to
prevent damage.
3. Install the ground cable connector to the terminal located
on the top of the motor assembly. Ensure that the cable
is oriented to prevent interference with the down tube.
See Fig 8.
Ensure proper connection of the power and communication
cables. Failure to properly connect the cables can lead
to operating issues.
4. Slide the down tube over the motor assembly mount bracket
ensuring that the cables are not pinched or placed into a
bind. Align the down tube so that the holes in the down
tube align with the holes in the motor assembly mount
bracket.
5. Attach the down tube to the motor assembly mount bracket
using the 6017838 5/16" dia. Torx screws and 6017838
washers supplied. Tighten the Torx screws using the
provided 6017872 Torx wrench.
Ensure downtube
cables are firmly
engaged
Downtube
fasteners
Downtube
Motor
assembly
Route ground wire
to avoid plug
Motor ground
fastener
Fig. 8