19
20
TECHNICAL FEATURES
City Names and Their Screen Displays for
the Language set in the Regional Settings
Parameters for the Turkish Language Selection
ADANA
Adana
+2:00
ADIYAM
Adýyaman
+2:00
AFYONK
Afyon
+2:00
AGRI
Aðrý
+2:00
AKSARA
Aksaray
+2:00
AMASYA
Amasya
+2:00
ANKARA
Ankara
+2:00
ANTALY
Antalya
+2:00
ARDAHA
Ardahan
+2:00
ARTVIN
Artvin
+2:00
AYDIN
Aydýn
+2:00
BALIKS
Balýkesir
+2:00
BARTIN
Bartýn
+2:00
BATMAN
Batman
+2:00
BAYBUR
Bayburt
+2:00
BILECI
Bilecik
+2:00
BINGOL
Bingöl
+2:00
BITLIS
Bitlis
+2:00
BOLU
Bolu
+2:00
BURDUR
Burdur
+2:00
BURSA
Bursa
+2:00
CANAKK
Çanakkale
+2:00
CANKIR
Çankýrý
+2:00
CORUM
Çorum
+2:00
DENIZL
Denizli
+2:00
DIYRBK
Diyarbakýr
+2:00
DUZCE
Düzce
+2:00
EDIRNE
Edirne
+2:00
ELAZIG
Elazýð
+2:00
ERZINC
Erzincan
+2:00
ERZURU
Erzurum
+2:00
ESKISE
Eskiþehir
+2:00
GANTEP
Gaziantep
+2:00
GIRESU
Giresun
+2:00
GUMUSH
Gümüþhane
+2:00
HAKKAR
Hakkari
+2:00
HATAY
Hatay
+2:00
IGDIR
Iðdýr
+2:00
ISPART
Isparta
+2:00
ISTANB
Ýstanbul
+2:00
IZMIR
Ýzmir
+2:00
KMARAS
Kahramanmaraþ
+2:00
KARABU
Karabük
+2:00
KARAMA
Karaman
+2:00
KARS
Kars
+2:00
KASTAM
Kastamonu
+2:00
KAYSER
Kayseri
+2:00
KIRIKK
Kýrýkkale
+2:00
KIKLA
Kýrklareli
+2:00
KIRSEH
Kýrþehir
+2:00
KILIS
Kilis
+2:00
KOCAEL
Kocaeli
+2:00
KONYA
Konya
+2:00
KUTAHY
Kütahya
+2:00
MALATY
Malatya
+2:00
MANISA
Manisa
+2:00
MARDIN
Mardin
+2:00
MERSIN
Mersin
+2:00
MUGLA
Muðla
+2:00
MUS
Muþ
+2:00
NEVSEH
Nevþehir
+2:00
NIGDE
Niðde
+2:00
ORDU
Ordu
+2:00
OSMANI
Osmaniye
+2:00
RIZE
Rize
+2:00
SAKARY
Sakarya
+2:00
Program Number
5 Years
Battery Shelf Life
32
Screen Size
Accuracy
Power Consumption
Mechanical Features
Equipment Protection Class
Ambient Temperature
Protection Class
Installation
Dimensions
Package Weight
Quantity in 1 Package
Refresh Time
Output Contact
Operating Voltage (Un)
Electrical Features
1,3” LCD
1 sec. /day
< 5 VA
1 sec.
2 C/O , 16 A / 4000 VA
Class II ( )
-10°C, +55°C
IP20
Rail Mount
PK25
0,2 kg
5 pcs.
Please look at the side label
Displayed
Name
Cities
Time
Zone
Displayed
Name
Cities
Time
Zone
Displayed
Name
Cities
Time
Zone
Due to the structure of LCD screens, the liquid inside them starts
to freeze below its operating temperature. This causes the screen
to respond slower or not respond at all. Device's other functions
are not affected from this and it opens/closes its relays as
programmed. After the device temperature rises back to the
operating range, LCD screen starts to work normally.
Note: The contact resistance at
ohmic load ( eg: Incandescent
bulb,Resistance devices ) is 16A.
It is recommended to use a
contactor if the inductive load
(eg: AC motor, fluorescent,etc.)
or capacitive load (eg: Led
Drivers,UPS, Fluorescent
( Electronic Ballast), etc.) switch.
Otherwise adhesion may
occur in relay contacts.