Module Placement in a Matrix E7 Chassis
2-2 Network Requirements
In
normal
usage
(and
typical
implementations)
there
is
no
need
to
enable/disable
ports
for
Link
Aggregation.
The
default
values
will
result
in
the
maximum
number
of
aggregations
possible.
If
the
switch
is
placed
in
a
configuration
with
its
peers
not
running
the
protocol,
no
aggregations
will
be
formed
and
the
DFE
modules
will
function
normally
(that
is,
Spanning
Tree
will
block
redundant
paths).
For
details
about
the
commands
involved
with
configuring
the
Link
Aggregation
function,
refer
to
the
Enterasys
Matrix
DFE
‐
Platinum
Series
Configuration
Guide
.
Module Placement in a Matrix E7 Chassis
If
you
want
to
mix
6x1xxx,
6x2xxx,
6x3xxx,
and
7H43xx
‐
xx
series
modules
in
the
same
Matrix E7
chassis,
it
is
necessary
to
have
a
DFE
bridging
module
installed
and
follow
the
instructions
described
in
“
Module
Placement
and
Rules
”
on
page 3
‐
7
to
successfully
bridge
data
traffic
to
some
or
all
modules
in
the
Matrix E7
chassis.
At
the
time
of
this
printing,
the
FTM1
‐
to
‐
FTM2
bridging
modules
available
are:
7H4382
‐
25,
7H4382
‐
49,
7H4383
‐
49,
and
7H4385
‐
49.
1000BASE-SX/LX/ELX Network
Optional
Mini
‐
GBICs
installed
in
the
7G4280
‐
19
front
‐
panel
ports
1
through
18,
or
in
an
optional
network
expansion
module
provide
Gigabit
Ethernet
connections
operating
at
1000 Mbps
(1 Gbps).
The
device
at
the
other
end
of
the
fiber
‐
optic
connection
must
meet
IEEE
802.3
‐
2002
Gigabit
Ethernet
requirements
for
the
devices
to
operate
at
Gigabit
speed.
Refer
to
Appendix A
for
further
details
on
Mini
‐
GBIC
specifications.
1000BASE-T Network
The
7G4280
‐
19
and
optional
network
expansion
module
also
support
Mini
‐
GBICs
for
copper
wire
connections
through
RJ45
connectors,
which
can
operate
up
to
1000 Mbps.
The
device
at
the
other
end
of
the
twisted
pair
segment
must
meet
IEEE 802.3
‐
2002
1000BASE
‐
T
network
requirements
for
the
devices
to
operate
at
Gigabit
speed.
Note:
The optional Mini-GBIC copper wire connection supports Category 5 UTP cabling
with an impedance of between 85 and 111 ohms for 1000 Mbps operation.
Summary of Contents for Matrix 7G4280-19
Page 2: ......
Page 12: ...x...
Page 27: ...LANVIEW Diagnostic LEDs DFE Platinum Series Hardware Installation Guide 1 7...
Page 28: ...LANVIEW Diagnostic LEDs 1 8 Introduction...
Page 64: ...Completing the Installation 3 34 Installation...
Page 80: ...Regulatory Compliance A 8 Specifications...
Page 90: ...Memory Replacement Procedures B 10 Mode Switch Settings and Installing Options...