Redundant Power Supply Specifications
Enterasys 800-Series Hardware Installation Guide A-7
08A-RPS-150P
Specifications
provides the specifications for the 08A-RPS-150P.
08A-RPS-500
Specifications
provides the specifications for the 08A-RPS-500.
Table A-4 08A-RPS-150P
Specifications
Item
Specification
Electrical
AC Input Frequency Range
AC Input Voltage Range
Output Voltage
Output Current
Maximum Output Power
47–63 Hz
85–264 Vac
12 Vdc
1.0 A min., 8.5 A or 13.0 A max.
102 W or 156 W continuous
Physical
Dimensions
19.6 H x 5.2 W x 25.7 D (cm)
7.7 H x 2.04 W x 10.1 D (in.)
Net Weight (Unit Only)
Gross Weight (Packaged Unit)
1.75 kg (3.85 lb)
3.20 kg (7.04 lb)
MTBF
400,000 Hours
Environmental
Operating Temperature
0°C to 50°C (32°F to 122°F)
Storage Temperature
-40°C to 85°C (-40°F to 185°F)
Operating Relative Humidity
10% to 90% RH
Table A-5 08A-RPS-500 Specifications
Item
Specification
Electrical
AC Input Frequency Range
AC Input Voltage Range
AC Input Current
DC Output
Maximum Output Power
50–60 Hz
100–240 Vac
10 A maximum at 115 Vac, 60 Hz
5.0 A maximum at 230 Vac, 50 Hz
-54 Vdc, 7.5 A maximum
+12.0 Vdc, 1.0 A minimum, 10.5 maximum
500 W
Physical
Dimensions
4.4 H x 19.9 W x 44.1 D (cm)
1.7 H x 7.8 W x 17.4 D (in.)
Net Weight (unit only)
Gross Weight (1 unit and packaging)
3.47 kg (7.63 lb)
4.95 kg (10.89 lb)
Summary of Contents for 08G20G2-08
Page 2: ......
Page 12: ...x...
Page 20: ...Getting Help xviii About This Guide...
Page 28: ...Features 1 8 Introduction...
Page 70: ...Completing the Installation 2 42 Installation...
Page 78: ...Removing the Switch from a Rack 3 8 Troubleshooting...