background image

ChemloCk PFA And PP Filter housings instAllAtion And use mAnuAl

ChemloCk PFA And PP Filter housings mAnuAl 

entegris, inC.

Installation

Facility Requirements

Housing should be plumbed with ability to isolate  

both upstream and downstream flows as required  
for filter changeout.

Mounting

PFA Housing

Components are double-wrapped for cleanroom  
use. Handle components according to your  
cleanroom procedures.

suggested mounting method #1:  
Customer-supplied mounting Plate

1. Use screws and nuts (part no. YY5600010) to  

secure the housing head to your equipment  
or facility mounting bracket (Figure 1).

2. The Chemlock PFA housing can be installed  

either bowl 

UP

 or bowl 

DOWN

.

Figure 1.

mounting BrACket temPlAte

Use Figure 2 as a guide for drilling holes into  

a customer-supplied mounting plate, when  
mounting the Chemlock PFA head.

Figure 2. Chemlock PFA mounting template

suggested mounting method #2:  
l-bracket mounting

1. Use screws and nuts (part no. YY5600010)  

to secure the housing head to the L-bracket  

(part no. YY4610190,) available from Entegris  
(Figure 3). The Chemlock PFA housing can  

be installed either bowl 

UP

 or bowl 

DOWN

.

 

Figure 3.

Shown assembled with customer-

supplied mounting plate. If the 

mounting bracket is >12.7 mm (0.5”)

thick, longer screws must be used.

Mounting plate 

(NOT supplied)

<12.7 mm [0.5”] 

thick for use with

supplied screws

34.93 mm

(1.38”)

4 × clearance holes 

for 

3

8

” screws

Ø 12.70 mm (0.50”)

87.63 mm

(3.45”)

2 places

31.75 mm

(1.25”)

69.85 mm

(2.75”)

2 places

Ø 38.10 mm

(1.50”)

thru 2 places

12.07 mm

(0.48”)

Mounting template detail for reference only. 

Not shown to scale

PFA Mounting Template

Mounting template detail for reference only. 

Not shown to scale

L-bracket 

Mounting Template

4 × Ø 10.36 mm

      (0.41")

31.75 mm 

(1.25”)

31.75 mm 

(1.25”)

50.80 mm 

(2.00”)

188.72 mm 

(7.43")

101.60 mm 

(4.00")

Summary of Contents for Chemlock PFA

Page 1: ...CONTAMINATION CONTROL SOLUTIONS Chemlock PFA and PP Filter Housings Installation and use manual ...

Page 2: ...cations 2 PFA 2 PP 2 Dimensions 3 Minimum Space Requirements 3 Installation 4 Facility Requirements 4 Mounting 4 PFA 4 PP 5 O ring Installation and Removal 6 Filter Installation 7 Housing Integrity Testing 8 Cartridge Removal 9 Ordering Information 10 Accessories 10 Product Warranties 11 Terms and Conditions 11 For More Information 11 Table of Contents ...

Page 3: ...NMENT is required when used with toxic and hazardous chemicals All filter housings filters and other pressurized vessels must be double contained to prevent serious personal injury SAFETY CLOTHING eye protection and safety apparatus appropriate for the liquids in use must be worn during component changeout and startup Perform all operations with stan dard liquid handling procedures in accordance w...

Page 4: ...er 156 mm 6 1 431 mm 17 0 683 mm 26 9 3 4 S300 1 2 S300 170 mm 6 7 431 mm 17 0 678 mm 26 7 1 S300 1 2 S300 152 mm 6 0 431 mm 17 0 678 mm 26 7 1 S300 1 4 S300 170 mm 6 7 438 mm 17 2 686 mm 27 0 3 4 S300 1 4 S300 152 mm 6 0 438 mm 17 2 686 mm 27 0 1 PrimeLock 1 4 PrimeLock 222 mm 8 7 444 mm 17 5 694 mm 27 3 3 4 PrimeLock 1 4 PrimeLock 212 mm 8 4 444 mm 17 5 694 mm 27 3 PP Housing 3 4 FNPT 1 4 NPT 13...

Page 5: ...ate when mounting the Chemlock PFA head Figure 2 Chemlock PFA mounting template Suggested Mounting Method 2 L bracket Mounting 1 Use screws and nuts part no YY5600010 to secure the housing head to the L bracket part no YY4610190 available from Entegris Figure 3 The Chemlock PFA housing can be installed either bowl UP or bowl DOWN Figure 3 Shown assembled with customer supplied mounting plate If th...

Page 6: ...sary holes into a customer supplied mounting plate when mounting the Chemlock PP head Figure 5 Chemlock PP mounting template Suggested Mounting Method 2 L bracket Mounting 1 Use screws and nuts to secure the housing head to the L bracket part no YY66BRACK Figure 6 The Chemlock PP housing can be installed either bowl UP or bowl DOWN Figure 6 Shown assembled with customer supplied mounting plate and...

Page 7: ...he o ring 25 mm 1 below a 250 watt heat lamp for 1 minute Install the o ring while it is still warm 4 For all housings handle the o ring with care Insert the o ring into the groove and push the o ring securely and evenly in place DO NOT roll or twist the o ring 5 To remove the old o ring slide the hook end of the housing wrench tool under the o ring then slide the tool around the bowl Caution Use ...

Page 8: ...rt it into the housing bowl 3 Using the end of the bag the two finger tabs on the key can be used to turn the cartridge 1 4 turn then lock the cartridge in place NOTE Lock the cartridge in place by turning it clockwise 4 Attach and tighten the bowl to the housing head The housing can be mounted in either a bowl Up or bowl Down position 5 Adjust the torque setting to 45 N m if using an E FKM o ring...

Page 9: ...m for storage Housing Integrity Testing Prior to usage the piping system should be tested to check for leaks Follow your facility leak checking protocols WARNING IF SYSTEM IS SHUT DOWN IT IS NECESSARY TO RETIGHTEN THE HOUSING see previous steps IN ORDER TO PREVENT LEAKS Caution DO NOT tighten or adjust the plumbing at elevated temperatures 100 C as you may overtighten the fittings and create exces...

Page 10: ... housing If necessary allow the housing to cool to a workable temperature 2 Use the housing wrench to loosen the housing ring 3 Remove the bowl from the head 4 Turn the cartridge key to unlock the cartridge from the bowl 5 Lift the cartridge out of the bowl or tip the bowl to gently slide the cartridge out of the bowl To view a video showing correct procedures for o ring replacement and housing in...

Page 11: ... the key are still available under their usual catalog number Any standard 10 Code 0 cartridge can be used with the universal Chemlock housing Only Entegris Chemlock cartridges can utilize the cartridge locking mechanism Use of a Chemlock key or any other key with a third party cartridge shall void the warranty of the housing and may infringe one or more of Entegris pending or issued U S and forei...

Page 12: ...r is a registered trademark of Nippon Pillar Packing Company Inc For More Information Please call your Regional Customer Service Center today to learn what Entegris can do for you Visit www entegris com and select the Customer Service link for the center nearest you Terms and Conditions of Sale All purchases are subject to Entegris Terms and Conditions of Sale To view and print this information vi...

Reviews: