RAK131_ENG / 6.4.2021
14 / 24
User Interface
EVH161-HC000
EVH163-HC000
EVH321-HC000
EVH323-HC000
EVH161-HCR00
EVH163-HCR00
EVH321-HCR00
EVH323-HCR00
Connection to vehicle
Fixed cable, length 5m
Charging status
indication
4-color LED:
Green = Ready / Blue = Charging / Red = Error /
Yellow = Internal maintenance
Use access
Free access
Mobile application
Safety Features
EVH161-HC000
EVH163-HC000
EVH321-HC000
EVH323-HC000
EVH161-HCR00
EVH163-HCR00
EVH321-HCR00
EVH323-HCR00
Residual current device
RCD
Leakage detection integrated
RDC-DD, 6mA
RCD, type A 30mA must be in-
stalled in distribution board
Leakage detection integrated
RDC-DD, 6mA
Residual current circuit breaker
and over current protection
integrated, RCBO, 30mA
Miniature circuit
breaker
MCB
Max. 16A must
be installed in
distribution
board
Max. 32A must
be installed in
distribution
board
Control and
Communication
EVH161-HC000
EVH163-HC000
EVH321-HC000
EVH323-HC000
EVH161-HCR00
EVH163-HCR00
EVH321-HCR00
EVH323-HCR00
Operation mode
Standalone
Wireless
Bluetooth
Charging control
system
“Simplified control pilot” functionality, specified in EN IEC 61851-1:2019,
Annex A.2.3 is not supported.
ZEReady 1.2b and EVReady 1.4b are not supported.