RAK131_ENG / 6.4.2021
10 / 24
EVH163-HC000 / EVH323-HC000:
•
Install a residual current device (RCD type A, 30mA) and a circuit breaker (MCB max. 16A
or max. 32A depending on charger model) to the supply line. In addition follow local regu-
lations for the power supply line.
•
Do not connect these charger models to an IT network.
L1 L2 L3
L1
N
PE
Supply
Cu 2.5 - 10 mm²
PE L1 L2 L3 N
TN network