NB: During lengthy storage periods, the lithium battery may be passivated, and therefore unable to
supply the current needed for the LYNX 3400 to operate. To depassivate it:
-
Short-circuit its terminals with a 47-ohm 3-W resistor
-
Wait for a noticeable rise in the resistor's temperature (10 to 30 seconds depending on the
batteries)
-230-V AC external power supply (LV power supply option)
The LYNX 4400's normal power source is low voltage 230 V, which is available on site. The LV is supplied
to the LYNX 4400 by a 2 x 1.5mm² U1000RO2V type cable – not supplied. LYNX 4400s do not need to be
connected to the neutral earth.
Connecting the J4 connector
Insert the cable via the LYNX 4400's cable grommet.
Connect the cable's neutral and phase wires as follows:
-
-
Neutral, to the left-hand terminal.
-
-
Phase, to the right-hand terminal.
Check the condition of fuse F1. A 5X20 F type (250 mA)
spare fuse is available on the lower left-hand side
of the detector.
N PH