RAK107
22.5.2018
40
9.6.6
Diagnostic board
Before changing the diagnostic card 95IPD, make sure that it holds
correct firmware for the display. On the PCB also has a rotary switch
S3 that needs to be set to correct position. Verify position from old
diagnostic card. Diagnostic board is installed to a mounting plate that
has snap-on connection to DIN-rail.
How to change the 95IPD diagnostic board:
1.
Open the display’s front door and TFT LCD –element.
2.
Power off the display from the main switch Q1.
3.
Disconnect the diagnostic board’s cables and remove from
mounting plate.
4.
Change new board into place.
5.
Secure with screws and reconnect cables.
6.
Check rotary switch S3 position.
7.
Power on the display from the main switch Q1.
8.
Close the display’s TFT LCD –element and front door.