TM
BrightEye 75
BrightEye 75 - Page 13
Timing Menu
Use the Timing Menu to set the parameters of the TBC and Frame Sync
functions. The timing function operates in one of three modes:
1. When the
Frame Sync
control is turned
On
and a proper reference signal
is connected to the
Ref In
BNC, the video output of the unit is synchronous
and locked to the external reference. The output may be timed with respect
to the Ref In using the timing controls. In this case, the unit will accept
asynchronous video and time base errors will be corrected.
2. When the
Frame Sync
control is turned
On
and no reference signal is
connected, the unit acts as a time base corrector only. The output is not syn-
chronous to any reference, including the input. This mode allows a noisy
input signal to be time base corrected for a clean, stable output.
3. When the
Frame Sync
control is turned
Off
, any reference signal to the
Ref In
BNC is ignored. The video input is synchronous to the video output
when a nearly perfect, clean video input signal is present (no time base cor-
rection required).
The following timing control is available when the
Frame Sync
function is
On:
• Timing
– adjust the vertical and horizontal timing of the signal with
respect to the reference input. Click the
Default
button to return to the
default value.
Use the following control to enable the
Frame Sync
function:
• Frame Sync
– set the
Frame Sync
function to
On
to genlock to the
reference input to the module, or to
Off
for no Frame Sync.