6

A burst frequency can be set for treating chronic pains, where the use of continuous stimulation with a low
pulse frequency would be too painful. A burst consists of an interrupted train of pulses. Each burst lasts
for 100 ms and the burst rate can separately be adjusted. See paragraph 10 for details. With this milder
TENS waveform it is easier to exceed the motorial threshold stimulus.

5 Package Contents

1427940 TensMed 911

5.1

Standard Accessories

The following accessories are included with your TensMed 911:

3444001

Electrode cable 2 mm, 2 pc in conformity with FDA CFR 898

3444057

EN-Trodes, self adhesive electrode 50x50 mm, 1 set 4 pc.

1427755

User manual TensMed 911
Alkaline AA 1,5 Volts (LR6) Batteries
Carry Pouch

5.2

Optional Accessories

3444056

EN-Trodes, self adhesive electrodes, size 32mm Ø, 1 pack = 10 sheets of 4 pc

3444135

EN-Trodes, self adhesive electrodes, size 50mm Ø, 1 pack = 10 sheets of 4 pc

3444143

EN-Trodes, self adhesive electrodes, size 70mm Ø, 1 pack = 10 sheets of 4 pc

3444057

EN-Trodes, self adhesive electrodes, size 50x50mm, 1 pack = 10 sheets of 4 pc

3444058

EN-Trodes, self adhesive electrodes, size 50x90mm, 1 pack = 10 sheets of 4 pc

3444146

EN-Trodes, self adhesive electrodes, double lead, size 50x100mm, 1 pack=10 sheets of 2pc

6 Installation

Insert Batteries:
Insert two batteries. (A diagram inside the battery compartment shows how to insert the batteries
correctly.)

To check if the batteries have been correctly fitted, press the ON/OFF button once and the LCD display
will start up and the LED Lights will come on. Press the ON/OFF button again to switch the unit off.

Use only AA Alkaline 1.5 volt batteries (LR6).
Do not mix old and new batteries.

The battery contains material that is noxious to environment. You should attend the local regulations
when disposing the battery.

Attach Leads:
Unravel leads and insert the plug(s) into either sockets in the end of the unit. If using only one lead use L1
(as marked on the unit next to the socket).

Attach Electrodes to leads:
Remove electrodes from the bag and connect to the leads.
Simply push the plug on the electrode pigtail into the socket on the lead.

Summary of Contents for TensMed 911

Page 1: ...TensMed 911 User Manual...

Page 2: ...Copyright Enraf Nonius B V P O Box 12080 3004 GB Rotterdam The Netherlands Tel 31 0 10 20 30 600 Fax 31 0 10 20 30 699 info enraf nonius com www enraf nonius com Part number 1427 755 41 August 2005...

Page 3: ...1 TensMed 911 User Manual...

Page 4: ...c effects 7 7 4 Current density 7 7 5 Connection and disconnection reactions 7 8 Operating Instructions 8 8 1 Operator Controls 8 8 2 Intensity adjustment 9 8 3 Safety features 9 8 4 Additional featur...

Page 5: ...ct Liability law implies amongst other things that once a period of 10 years has elapsed after a product has been brought into circulation the manufacturer can no longer be held responsible for possib...

Page 6: ...with air oxygen or nitrous oxide This device should be kept out of the reach of children CAUTION Read understand and practice the precautionary and operating instructions Know the limitations and haza...

Page 7: ...ing pregnancy Stimulation should not be applied over swollen infected or inflamed areas of skin eruptions e g phlebitis thrombophlebitis varicose veins etc See also chapter 3 Precautionary Instruction...

Page 8: ...0mm 1 pack 10 sheets of 4 pc 3444057 EN Trodes self adhesive electrodes size 50x50mm 1 pack 10 sheets of 4 pc 3444058 EN Trodes self adhesive electrodes size 50x90mm 1 pack 10 sheets of 4 pc 3444146 E...

Page 9: ...sponges to keep the effects to a minimum Make sure that the sponges are kept well moistened and place the thick side of the sponge between the flexible rubber electrodes and the patient 7 4 Current de...

Page 10: ...ters that can be selected are Waveform Frequency Pulse Width Constant or Burst Timer The PAUSE function interrupts a Program which is using the Timer It only operates when a program is running with In...

Page 11: ...is a low battery detector in the unit The LCD screen will flash the symbol of a battery when the batteries need replacing 8 5 Usage monitor USAGE MONITOR For Professional Use A Usage Monitor is includ...

Page 12: ...E Pulsing Tapping Chronic pain nausea travel and morning sickness Avoid use on traumatised muscles F Pulsing Tapping Most types of acute and chronic pain G Varies Acute and chronic pain H Varies Acut...

Page 13: ...locking 8 8 User Maintenance 8 8 1 Cleaning of apparatus To clean the unit turn it off Clean the unit with a damp cloth Do not use abrasive cleaners A small amount of mild household detergent may be u...

Page 14: ...n 12 seconds Program M 1Hz to 150Hz Intensity modulation Program G intensity down to 70 and back over 10 seconds Pulse Width modulation Program H pulse width modulation from 250 s to 50 s and back in...

Page 15: ...lass according to IEC 60601 1 type BF Dimensions 144 x 80 x 27 5 mm h x w x d Weight 180 gram included batteries Environmental conditions for transport and storage Temperature 10 to 50 C Relative humi...

Reviews: