![Enplus AC044K-BE-24 User Manual Download Page 6](http://html.mh-extra.com/html/enplus/ac044k-be-24/ac044k-be-24_user-manual_2414036006.webp)
- 5 -
Electrical
Parameter
Input Voltage
380V
±
20%
Input Frequency
50Hz
Max Power
2x22kW
Output Voltage
380V
±
20%
Max Output Current
32A
Standby Power
<10W
Environmental
Index
Application Place
Indoor / Outdoor
Working Temp
-30
℃
~ +50
℃
Working Humidity
5% ~ 95% without condensation
Working Altitude
<2000m
Protection Grade
IP54
Cooling Method
Natural air cooling
Safety Standard
EN 61851-1: 2011, EN 61851-22: 2002
MTBF
100,000 hours
Special Protection
Anti UV design
Safety Design
Protections from over voltage, under voltage, over load, short circuit,
current leakage, ground fault, over temperature, under temperature, lighting
& surge.
Communication
Charger v.s. EN-GATE communication: CAN
EN-GATE v.s. Backend communication: Ethernet
Internet Communication Protocol: OCPP 1.6
1.4 Performance and Characteristics
Performance:
LED Indicator: Different light color indicate different working status of the charger.
LCD Screen: Real-time display the charger status and charging data.
Touch Buttons: Four touch buttons to adjust the charger's configuration and settings.
RFID Card: Built-in card reader to realize the function of charging with RFID card. Scan RFID card
first to start charging, and scan RFID card again to end charging.
Emergency Stop Button:
In case of emergent issues happen, press the button to cut off charging output
for safety.