background image

 

00-02-0883 

2013-02-20 

Section 78

 

 
 
 

 

 

HelmView

 

Model HVS780 

Operations Manual 

1-800-548-1191 - http://www.partdeal.com - [email protected]

Summary of Contents for MURPHY HelmView HVS780

Page 1: ...00 02 0883 2013 02 20 Section 78 HelmView ModelHVS780 Operations Manual 1 800 548 1191 http www partdeal com info partdeal com ...

Page 2: ... and designs at any time The latest version of this manual can be found at www fwmurphy com BEFORE BEGINNING INSTALLATION OR OPERATION OF THIS MURPHY PRODUCT Read and follow all installation operation instructions Please contact MURPHY immediately if you have any questions 1 800 548 1191 http www partdeal com info partdeal com ...

Page 3: ... THIS PAGE INTENTIONALLY LEFT BLANK 1 800 548 1191 http www partdeal com info partdeal com ...

Page 4: ...ng your HVS780 Display for the First Time 2 Product Features 4 Power Up 4 Main Menu 4 Gauge Display 5 Engine Diagnostics 7 Fault Code Popups 9 User Settings 10 Utilities 17 Data Logger 18 Trip Parameters 19 1 800 548 1191 http www partdeal com info partdeal com ...

Page 5: ...ble for the screen being displayed Function Keys The function keys correspond to the soft key commands and allow selections to be made accordingly MENU Key Pressing the MENU key at any time displays the list of menu options ENTER Key Pressing the ENTER key will select the option displayed much like the ENTER key on a keyboard The ENTER key also brings up the soft keys Press once to display the lef...

Page 6: ...configuration is set up there is no need to revisit or change any of the settings NOTE If you require assistance during the set up process contact Murphy Customer Support at the office nearest to you see the address block on the last page 1 At the main menu press the soft key to the left of Utilities 2 The Utilities sub menu is displayed 1 800 548 1191 http www partdeal com info partdeal com ...

Page 7: ...he Restore Defaults key to return to the default settings Service Reminders Factory defaults for Service Reminders apply automatically on first use of the HelmView HVS780 Normally you should not need to access the Service Reminders screen FACTORY DEFAULT VALUES Change Engine Oil Default interval 50 0 Hrs Chang Air Filters Default interval 75 0 Hrs Change Hydraulic Oil Default interval 100 0 Hrs Se...

Page 8: ...tion When the ignition is turned on the HelmView display powers up and the engine health statistics can be viewed via preset gauges To see more gauge screens press the lower left or right Function keys Main Menu The main menu is activated at any time by pressing the Menu key on the display 1 800 548 1191 http www partdeal com info partdeal com ...

Page 9: ...e top of the page Gauge Display The Gauge Display screen consists of several predefined layouts that contain combinations of analog gauges straight bar gauges or digital text readouts These screens are displayed upon startup To scroll through the various gauge screens press the Prev and Next soft keys This can be repeated until all screens have been viewed The currently displayed screen will stay ...

Page 10: ...r Settings section of this manual Day Night Allows you to toggle the display screen between Day View and Night View NOTE This feature can also be changed in the User Settings see this section of this manual Day View Night View Red Night View Blue Previous and Next These soft keys allow you to scroll through and display the various gauge screens Video When enabled displays either full screen video ...

Page 11: ...rious gauge screens NOTE For instructions on how to turn screens ON or OFF refer to the User Settings section of this manual Engine Diagnostics Choose Engine Diagnostics from the Menu for the HelmView 780 to query the Engine Control Unit s and provide feedback on any activated service codes Faults displayed are based on engine or auxiliary sources 1 800 548 1191 http www partdeal com info partdeal...

Page 12: ...of the SPN number FMI Failure Mode Indicator fault code The FMI is defined by SAE J1939 If not translated into text see the SAE standard or the engine manufacturer s literature Count The number of times the event has been flagged Description The common SPN s and FMI s have a text description stored in the HelmView 780 display If there is no text then define this SPN FMI by referring to the engine ...

Page 13: ...n press the soft key on the upper right next to the Hide icon The popup will disappear however the Warning or Stop icon will remain on the screen to indicate there is still a fault Pressing Hide does not clear the fault it only hides the popup message When a fault code has been hidden a Recall icon will remain on the right side When this soft key is pressed the fault code will again be displayed W...

Page 14: ...tes through the options To change an option press the corresponding soft key next to the desired soft key command Ambient Light Night and Day options are provided for ambient lighting along with a Backlight Toggle The screens below illustrate these options When the ambient lighting settings are changed in User Settings the power on default is changed To choose either Red or Blue night viewing mode...

Page 15: ... are unassigned Hold the soft key down for 5 seconds to turn OFF the backlight This function only turns the backlight off The unit continues to operate as normal but with no backlight Press any soft key to Wake the backlight In the screen below you can use the unassigned upper right soft key to access the Backlight Toggle mode and the second soft key down to switch between night and day Brightness...

Page 16: ...rd Language This option allows you to select the language that will be displayed on the HelmView HVS780 Available languages include English French Spanish German Italian and Chinese Languages are selected from the soft keys Press More to view additional languages NOTE English is the standard language for this configuration Additions to this feature will be provided in future software updates or po...

Page 17: ...d use the grey up and down arrows to select specific screens and the On Off button to turn screens on or off To select a Home screen to display every time the unit is powered up select the Home check box for only one screen Video Mode Change accordingly to match video input either NTSC National Television Standards Committee used primarily in North and South America or PAL Phase Alternating Line u...

Page 18: ...ded via GPS signal through your GPS receiver Most GPS devices convert GPS time to UTC Coordinated Universal Time Time Zones are normally offset from UTC by a whole number of hours UTC 12 to UTC 14 Use the Up and Down Arrows to scroll to your time offset The range offered is 12 to 13 1 800 548 1191 http www partdeal com info partdeal com ...

Page 19: ...the soft key for DST ON To turn DST OFF press the soft key for DST Off Save Once all changes have been made press Save and follow the on screen instructions The following confirmation screen is displayed Press the Enter soft key to Save or press the Menu soft key to Cancel 1 800 548 1191 http www partdeal com info partdeal com ...

Page 20: ...ubleshooting you can use this as a last resort to reset the display to a known state To restore the default user settings press the soft key for Restore Defaults The following confirmation screen displays Press the Enter soft key to Restore Defaults or press the Menu soft key to Cancel the action 1 800 548 1191 http www partdeal com info partdeal com ...

Page 21: ...Settings screen displays the current software version loaded on the HVS780 display You can set individual settings for the available options and Save or choose to select Restore Defaults for the factory settings The yellow Up and Down keys on the left allow you to move the cursor through J1939 Source Addresses fields While the cursor is highlighting a field the gray Up and Down keys scroll through...

Page 22: ...l 125 0 Hrs Service Machine Default interval 150 0 Hrs Using the gray up and down arrows highlight the appropriate service reminder and press the Reset button on the lower right hand side Data Logger Use the Data Logger function to record the J1939 parameters being read by the HelmView 780 The parameters recorded are defaulted to those that display on gauges and screens The recorded information ca...

Page 23: ...nt soft key to select J1939 and use SPN 182 Engine Trip Fuel to display fuel used during all or part of a voyage Press the adjacent soft key to select Calc The HelmView 780 will use all engine trip fuel data to calculate a fuel usage number The Trip Fuel gallons liters display on the GPS gauge screen To clear a trip press the soft key adjacent to the Reset Trip icon The following warning displays ...

Page 24: ...1 800 548 1191 http www partdeal com info partdeal com ...