Public data
Public data can be read by any NFC-capable device supporting the ISO/IEC 14443 Part 2
and 3 standards. No specific security measures are used to restrict read access to this data.
The following items are located in the public data area:
Product
Name
This
is
always
“
PTM216B
”
OEM
Name
This is an 8 byte field which is by default set to
“EnOcean®“
to identify EnOcean
GmbH as the manufacturer of this module. OEM Name and Manufacturer ID can be
configured by the customer as required to identify his PTM 216B based product, see
chapter
6.7.7
Manufacturer
ID
This is a 2-byte field Manufacturer ID is assigned by Bluetooth SIG and used to iden-
tify the manufacturer of a Bluetooth product, see chapter 4.6. This field is by default
set
to
0x03DA
(EnOcean
GmbH)
.
Product ID and Manufacturer ID can be configured by the customer as required to
identify his PTM 216B based product, see chapter 6.7.7
Static
Source
Address
This is a 4-byte field containing the four least significant bytes (the two most signifi-
cant bytes are always
0xE215
) of the static source address used by PTM 216B, see
chapter 4.4.1. Each PTM 216B is pre-programmed with an individual static source
address.
The Static Source Address can be configured by the customer as required to identify
his
PTM
216B
based
product,
see
chapter
6.7.4
Hardware
Revision,
Software
Revision
and
NFC
Revision
These
fields
identify
the
device
revision
Telegram
sequence
counter
This is a 4-byte field which is initialized to zero during manufacturing and incre-
mented for each transmitted telegram. Receivers shall never accept telegrams con-
taining sequence counter values equal or less than previously received values to
avoid
replay
attacks.
Changing the Static Source Address, Manufacturer ID and Product ID fields is only possible
via protected data access as described below to prevent unauthorized modification.
For security reasons, the telegram sequence counter cannot be written or reset by any
mechanism.