ENMET LC-SERIES Operation And Maintenance Manual Download Page 22

LC-Series Controller: 1-4 Channel

 

ENMET 

 

Manual Revision Date – June 13, 2017

 

P a g e

 | 

21

 

Manual Part No. – 80003-050 

 

 

8.0 Terms and Conditions 

8.1 Ordering Information 

Address orders to:  

ENMET 

Attention: Customer Service Department 

680 Fairfield Court 

Ann Arbor, MI 48108 

Email Orders: 

[email protected] 

Phone: 734-761-1270 

Fax: 734-761-3220 

You may also contact our customer service department by email [email protected].  MINIMUM ORDER IS $50.00. 

 

8.2  Delivery 

Unless Seller otherwise specifies, delivery will be made: FOB Ann Arbor, MI and/or FOB Bowling Green, KY.  Title and risk of 
loss shall pass to Buyer at that point.  Shipping and handling charges will be Prepaid and Added to Buyer’s invoice.  Buyer may 
request shipping be charged to their own account with a preferred carrier.  Seller shall have the right to choose means of 
transportation and to route shipment when specific instructions are not included with Buyer’s order.  Seller agrees to deliver the 
goods and services, within the time, in accordance with specifications, at the prices specified on the face hereof.  Buyer’s orders to 
this quotation are not subject to cancellation or deferment of delivery without indemnification of loss to the Seller resulting there 
from.  Seller shall not be liable to Buyer for any loss or damage sustained on account of this delay or nonperformance due to 
causes beyond Seller’s control and without his fault or negligence.  Where performance of the terms here is contingent upon timely 
delivery of goods or services by the Buyer and such delivery is in default, Seller shall be indemnified for any damage or loss 
resulting there from, and/or by extension of Seller’s delivery commitment, as applicable. 

 

8.3  Payment Terms 

Payment Terms are Net 30 Days from the date of shipment from Seller unless otherwise noted.  All shipping and handling costs 
will be charged to Buyer on a Prepaid and Add basis.  Buyer has the option of paying for shipping by charging its own account 
with a carrier 

 

8.4  Warranty Information and Guidelines 

The Seller warrants new instruments to be free from defects in workmanship and material under normal use for a period of one 
year from date of shipment.  The warrant covers both parts and labor excluding calibration and expendable parts such as filters, 
detector tubes, batteries, etc.  If the inspection by the Seller confirms that the product is defective, it will be repaired or replaced at 
no charge, within the stated limitations, and returned prepaid to any location in the United States.  The Seller shall not be liable for 
any loss or damage caused by the improper use or installation of the product.  The Buyer indemnifies and saves harmless the Seller 
with respect to any loss or damages that may arise through the use by the Buyer or others of this equipment.  This warranty is 
expressly given in lieu of all other warranties, either expressed, implied or statutory, including that of merchantability, and all 
other obligations, or liabilities of ENMET, LLC for damages arising out of or in connection with the use or repair or performance 
of the product.  In no event shall ENMET, LLC, be liable for any indirect, incidental, special or consequential damages or for any 
delay in the performance by ENMET, LLC, which may arise in connection with this equipment.  ENMET neither assumes nor 
authorizes any representatives or other persons to assume for it any obligation or liability other than that which is set forth herein.  
Buyer agrees to indemnify and save harmless Seller for any damage or loss from lawsuits against Seller by reason of manufacture 
of sale of materials, parts, or use of processes resulting from Buyer’s design specifications.  Any patent, design, pattern, tool, die, 
jig, fixture, drawing, test equipment, or process furnished by Seller; whether possessed by the Seller before the date of this 
quotation, or devised or acquired by Seller during performance of the terms of this quotation, shall remain the property of the 
Seller except by specific stipulation on the face hereof.  Seller reserves the right, without liability, for damage or loss, to destroy 
Buyer’s drawings, specifications, patterns and special tools supplied by Buyer for performance of the terms on the face hereof, 
unless Buyer gives notice of the disposition of such items. 
 

8.5  Return Policy 

All returns for credit must be approved in advance by ENMET, LLC.  

Such returns are subject to a minimum $50.00 or 20% 

restocking charge, whichever is greater.  

Approval of equipment for return is totally at the discretion of ENMET, LLC.  

All 

requests for return/exchange must be made no later 30 days of the original shipping date from ENMET.  The actual amount of any 
resulting credit will not be determined prior to a complete inspection of the equipment by ENMET.  Calibration gas cylinders 
cannot be returned or restocked. 
 

Summary of Contents for LC-SERIES

Page 1: ...ENMET 680 Fairfield Court Ann Arbor MI 48108 734 761 1270 Fax 734 761 3220 www enmet com LC Series Controller 1 4 Channel Operation and Maintenance Manual...

Page 2: ...ler Module 12 5 2 Analogue Output Configuration 14 5 2 1 4 20mA Current Source 14 5 2 2 4 20mA Current Sink 15 5 2 3 1 5V Voltage Output 16 6 0 MAINTENANCE 17 7 0 TECHNICAL DATA AND SPECIFICATIONS 18...

Page 3: ...ET and delivered to the carrier in good condition When it was picked up by the carrier at ENMET it legally became your company s property If your shipment arrives damaged Keep the items packing materi...

Page 4: ...er most indication of Fault Condition Keypad Buttons 4 2 as indicated in figure 1 that are used during normal operation and 2 that are used during setup and programming Menu Main Select Switch Increas...

Page 5: ...V DC supply can be used to power the control unit The location of installation should be chosen with regard to the following This equipment should not be located near to known sources of heat Operatin...

Page 6: ...LC Series Controller 1 4 Channel ENMET Manual Revision Date June 13 2017 P a g e 5 Manual Part No 80003 050 LC 4 Control Unit Figure 2 Mounting LC Series...

Page 7: ...ly would suffice AC Mains Connection The power supply board has three screw terminals connector assigned for the connection of an AC supply Pin 1 Earth Pin 2 Live input Pin 3 Neutral input Recommendat...

Page 8: ...ny modifications regardless of the type and quantity of detector heads being used TRACO POWER FG AC N AC L Input 100 240 VAC 47 63 Hz 0 375 A max Output 24VDC 625 mA TML 15124 Fault relay Fuse 1 Fuse...

Page 9: ...3 Hz 0 375 A max Output 24VDC 625 mA T ML 15124 Display PCB Connector E L N 24V 0V 15 16 17 18 OUTPUT 4 20 mA SOUNDER SOUNDER J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 D5 D4 100 240 VAC D C FLT L...

Page 10: ...13 14 J1 J2 J3 J4 J5 J6 J7 J8 J9 FS1 FS2 SW1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Power supply sectionI O interface section Channel Note connections 12 13 may not be fitted o...

Page 11: ...s Pin 13 Signal In 1 5 Vdc Pin 14 Signal In 4 20mA Pin 15 Voltage Out to S T Pin 16 Ground to S T Chanel 2 Pins 25 to 36 The same functions as 13 to 24 Chanel 3 Pins 37 to 48 The same functions as 13...

Page 12: ...ment e g cranes doors etc Install all cables neatly and securely Detectors for gases that are lighter than air should be positioned at or below a high level Detectors for gases that are heavier than a...

Page 13: ...alarm level 3 Yellow LED indication of fault condition An Audible signal is also provided by a sounder mounted within Microcontroller module This provides a local audible tone during alarm or conditi...

Page 14: ...thers OFF J1 J2 J3 J4 J5 J6 J7 J8 J9 Connect the wires from the detector head to connector on the input module observing the following Detector Head Label 4 20mA Loop Channel 1 Pin Number Channel 2 Pi...

Page 15: ...librated if in use refer to MCU Software Configuration and System Calibration Manual 5 2 1 4 20mA Current Source Chart record er 0V Alarm level1 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 Alarm le...

Page 16: ...1 26 27 28 29 30 31 32 33 34 35 36 Channel 2 38 39 40 41 42 43 44 45 46 47 48 Channel 3 50 51 52 53 54 55 56 57 58 59 60 Channel 4 16 17 18 LC 1 15 13 25 37 49 19 20 The Input Module can also sink cur...

Page 17: ...41 42 43 44 45 46 47 48 Channel 3 50 51 52 53 54 55 56 57 58 59 60 Channel 4 16 17 18 LC 1 15 13 25 37 49 19 20 Chart recorder ve ve The LC Control Unit can provide a voltage output i e zero gas 1V f...

Page 18: ...has occurred Clean control unit casing using a clean cloth Clean detector heads using a clean DAMP cloth NOTE Use of a dry cloth would constitute a static hazard Inspect detector heads and ensure the...

Page 19: ...cates power ON LED Indications Option 2 Red Red Yellow Indicates alarm level 1 condition Indicates alarm level 2 condition Indicates fault condition Input Modules Number of channels 1 max Signal Input...

Page 20: ...dicates alarm level 3 condition Indicates alarm level 2 condition Indicates alarm level 1 condition Indicates fault condition Input Modules Number of channels 2 max Signal Inputs x 2 4 20mA Current Lo...

Page 21: ...d Red Red Yellow Indicates power ON Indicates alarm level 3 condition Indicates alarm level 2 condition Indicates alarm level 1 condition Indicates fault condition Input Modules Number of channels 4 m...

Page 22: ...the inspection by the Seller confirms that the product is defective it will be repaired or replaced at no charge within the stated limitations and returned prepaid to any location in the United State...

Page 23: ...the Service Request Form assists in the expedient service and return of your unit and failure to provide this information can result in processing delays ENMET charges a one hour minimum billing for...

Page 24: ...it Appears on Card RETURN SHIPPING METHOD UPS Ground UPS 3 Day Select UPS Next Day Air UPS ND Air Saver UPS 2 Day Air UPS Account FedEx Ground FedEx Air Express Saver FedEx Air Overnight Std FedEx Air...

Reviews: