Integrated Synchronous Servo Drives
HBI 22xx / HBI 26xx / HBI 32xx / HBI 37xx
Operating Manual Rev. 1.6
www.engelantriebe.de
page 33
Requirements on the incremental line:
Cable with twisted pair leads recommended.
Minimum wire cross-section: 0.25mm²
Connect the overall shield with the lowest possible impedance to protective earth.
Flexibility in accordance with the specific application, max. operating temperature ≤80°C.
Type recommendation
:
ENGEL original accessories:
Item no. 9900000578 (5m)
Cable assembly with M12 connection plug, open on one end,
8x 0.25mm² (shielding applied on sleeve nut)
Other providers:
Cable assembly with M12 connection plug
WAKS8-2/S366 (2m)
Cable assembly with M12 connection plug
WAKS8-5/S366 (5m)
Cable assembly with M12 connection plug
WAKS8-10/S366 (10m)
- as above -
Reference: ESCHA Bauelemente GmbH, Halver, www.escha.de
Note:
With the use of a T-connector, rotating receptacles for the HBI drives can no longer be
completely turned towards the motor shaft. With the use of a Y-connector, on the other hand,
the full range of rotation of the receptacle is usable.
Common Y-connectors with 45° / 225° coding of the contact inserts are normally not
mechanically suitable for use on HBI drives! Check for usability before use!