ENFORCER Proximity Card Reader
8
SECO-LARM U.S.A., Inc.
8.
Set the relay toggle mode
(Timed output or toggle; default: timed output)
:
Action
Reaction
Tap a master card 8 times
2 Beeps after first tap, 1 more beep after each
subsequent tap, LED flashes
GREEN
Wait 3 seconds
8 Beeps,
GREEN
flashes continue
Wait a second, and the mode
changes automatically
Beeps 1 time = normal mode
Beeps 2 times = toggle mode
Exit – The unit automatically exits to standby mode
Normal mode
– Use a user card to unlock the door, the door automatically locks after the
timer has expired.
Toggle mode
– Use a user card to unlock the door, then use a user card to relock the door.
9.
Please note that tapping the master card 9 times will have no effect.
10.
Set the beeper mode
(ON or OFF; default: ON)
:
Action
Reaction
Tap a master card 10 times
2 Beeps after first tap, 1 more beep after each
subsequent tap, LED flashes
GREEN
Wait 3 seconds
10 Beeps,
GREEN
flashes continue
Wait a second, and the mode
changes automatically
Beeps 1 time = beeper OFF
Beeps 2 times = beeper ON
Exit – The unit automatically exits to standby mode
NOTE
– When the beeping is programmed OFF, the proximity reader will still beep during the
programming mode.
ENFORCER Proximity Card Reader
SECO-LARM U.S.A., Inc.
5
Mounting Diagram:
Getting Started:
Card Types:
There are three basic types of cards used by the proximity reader:
•
Master card – Used for programming only. It does not give access to the protected premises.
•
User card – Used for access only.
•
Blank card – A card that has not yet been programmed into the proximity reader. Considered
to be an invalid card.
NOTE
–
The proximity reader can learn up to 5 master cards and 100 user cards.
LED Color Indicators:
LED Color
Status Indicated
BLUE
The proximity reader is powered on and in standby mode
GREEN
The proximity reader is in programming mode
RED
Indicates an error or invalid card
First-Time Power Up:
1.
After connecting power, the unit should beep once and the LED should be
BLUE
– The
proximity reader is ready to be programmed using the included pre-programmed master card
(marked with a red sticker).
2.
If after connecting power for the first time the LED is flashing
GREEN
, you must program a
master card by tapping any blank card to the reader.
3.
This will be followed by 2 short beeps and the LED should turn
BLUE
.
4.
The proximity reader is ready to be programmed using the master card you just created.
Included
case screw
Mounting
plate
Proximity
card
reader
Screw for mounting
plate to surface
Through
hole for
cables