Choosing a Location:
To prevent erratic operation and/or false alarms:
•
Wind will not directly cause false alarms, but
could cause leaves or similar objects to fly or
wave into the beams. Therefore, do not mount
near trees, bushes or other leafy vegetation.
•
Do not mount where the sensor could be
suddenly exposed to a bright light, such as a
floodlight or a passing automobile’s headlights.
Over time, a strong light can affect the life of the
sensor.
•
Do not let sunlight or any direct beam of light
enter the sensor. If needed, mount so the
reflector, not the sensor, faces the sun.
•
Do not mount where animals could break the
beams.
•
Do not mount where the sensor could be
splashed by water or mud.
Do not install the sensor in areas where it may be
splashed by water or direct sea spray.
Do not mount the sensor near trees, bushes or
other leafy vegetation.
Wiring Diagram:
•
Polarity does not matter for the power input
•
Connect the N.C. tamper terminal to the tamper circuit of an alarm control panel
1
2
3
4
5
6
7
(+)
(–)
COM
N.C.
N.O.
N.C.
N.C.
12~250 VAC/VDC
Alarm Output
Tamper Output
Avoid strong lights such as the sun or automobile
headlights shining directly on the sensor.
ENFORCER 50ft Large Reflective Beam Sensor
SECO-LARM U.S.A., Inc.
5
Installation:
Wall Mount (Sensor):
1.
Loosen the cover screw at the bottom of the sensor and remove the cover (
fig. 1
).
2.
Loosen the captive screw at the bottom of the sensor. Slide the mounting plate downwards and
remove it from the unit.
3.
Make a small hole in the rubber grommet.
4.
Pull the wires from the wall or pole through the grommet and then through the opening above
the terminals (
fig. 2
).
5.
Connect the wires to the terminals. See Wiring Diagram on page 4.
6.
Using the included mounting screws, secure the mounting plate to the wall or surface (
fig. 3
).
Use optional anchors for brick or drywall (not included).
7.
Slide the sensor into position on the mounting plate and secure it in place by tightening the
captive screw.
8.
Replace the cover and secure it by tightening the cover screw.
Wall Mount (Reflector):
1.
Loosen the captive screw at the bottom of the reflector. Slide the mounting plate downwards
and remove it from the unit.
2.
Using the included mounting screws, secure the mounting plate to the wall or surface. Use
optional anchors for brick or drywall (not included).
3.
Slide the reflector into position on the mounting plate and secure it in place by tightening the
captive screw.
Fig. 1
Pole Mount (Sensor and Reflector):
1.
Use a pole with a diameter of 1
1
/
2
” (38mm) to 1
3
/
4
” (45mm).
2.
Fix mounting bracket to the pole with the pole bracket using
the included long screws.
3.
Remove the mounting plate from the back of the sensor and
reflector units (
fig. 4
).
4.
Secure the mounting plate of the unit to the mounting bracket
using the included short screws.
5.
Slide the sensor and reflector into position on the mounting
plate and secure them in place by tightening the captive screw.
(Continued on next page.)