![Enfora Enabler-G Integration Manual Download Page 18](http://html.mh-extra.com/html/enfora/enabler-g/enabler-g_integration-manual_2411840018.webp)
Integration Guide
Version 1.11
GSM0000PB001
Page 17
1.11 - 4/22/03
5.2 Detailed Product Specifications
Physical Dimensions and Weight
Size (L x W x H)
67 mm x 42 mm x 5.4 mm
(2.64” x 1.65” x 0.21”)
Weight TBD
(Less than 4 oz.)
Climatic: Operational
Operating temperature
-20°C to +60°C
Note:
Upper temperature range can be extended
under certain operating conditions. Consult
application note TBD.
Relative humidity
5 - 95%
Solar radiation
Not Applicable
Air pressure (altitude)
70 kPa to 106 kPa (-400 m to 3000 m)
Climatic: Storage and Transportation
Duration
24 months
Ambient temperature
-4
0
C to +8
5
C
Relative humidity
5% to 95%, non condensing (at 4
0
C)
Thermal shock
-5
0
C to +2
3
C, +7
0
C to +2
3
C; < 5 min
Altitude
-400 m to 15,000 m
Mechanical: Operational
Operational vibration, sinusoidal
3.0 mm disp, 2 to 9 Hz; 1 m/s
2
, 9 to 350 Hz
Operational vibration, random
0.1 m
2
/s
3
, 2 to 200 Hz
Mechanical: Storage and Transportation
Transportation vibration, packaged
ASTM D999
Drop, packaged
ASTM D775 method A, 10 drops
Shock, un-packaged
150 m/s
2
, 11 ms, half-sine per IEC 68-2-27
Drop, un-packaged
4-inch drop per Bellcore GR-63-CORE
Mechanical: Proposed Standards
Transportation
ETSI Standard ETS 300 019-1-2 Class 2.3
Transportation
Operational
ETSI Standard ETS 300 019-1-3 Class 3.1
Operational
Storage
ETSI Standard ETS 300 019-1-1 Class 1.2 Storage