Euromax Pellet Stove Installation and Operation Manual
19
4.5 Installation Configurations
4.5.1 Installation Warnings, Cautions and Recommendations Reminder
PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED
THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR JOINTS
MUST BE SEALED AND FASTENED. CONSULT THE PELLET VENT MANUFACTURER’S
INSTRUCTION TO ENSURE PROPER INSTALLATION, CONSISTENT PERFORMANCE, AND
TO AVOID SMOKE AND ASH SPILLAGE.
USE RTV SILICONE (Room Temperature Vulcanisation), METALLIC TAPE, AND A MINIMUM
OF THREE SELF-TAPING SCREWS AT ALL JOINT CONNECTIONS TO ENSURE A TIGHT
SEAL.
THE CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF SPACE,
CLOSET OR SIMILAR CONCEALED SPACE OR FLOORS OR CEILING.
INSTALL VENTING SYSTEM AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
THE USE OF A SPARK ARRESTER AT THE END OF THE TERMINATION IS MANDATORY.
4.5.2 Through Wall Installation (Main Floor or Basement)
1. Position stove following clearances given in
Section 3,
Clearances to Combustible
Material
and following
vent manufacturer’s instructions. Then locate the position of the
exhaust pipe in the wall.
2. Install wall thimble as
per vent manufacturer’s instructions.
3. Attach enough piping length to go through the wall thimble and extend at least 6 inches
beyond the exterior wall.
4. Attach cap and seal outside wall thimbles with high temperature waterproof silicone
sealant.
Summary of Contents for Euromax EP00070
Page 64: ...64 Euromax Pellet Stove Installation and Operation Manual 10 Wiring Diagram ...
Page 77: ...Euromax Pellet Stove Installation and Operation Manual 77 SECTION B ...
Page 78: ...78 Euromax Pellet Stove Installation and Operation Manual SECTION C ...
Page 79: ...Euromax Pellet Stove Installation and Operation Manual 79 SECTION D SECTION E ...
Page 80: ...80 Euromax Pellet Stove Installation and Operation Manual SECTION F SECTION G ...
Page 81: ...Euromax Pellet Stove Installation and Operation Manual 81 SECTION H SECTION I ...
Page 82: ...82 Euromax Pellet Stove Installation and Operation Manual SECTION J SECTION K ...