26
Euromax Pellet Stove Installation and Operation Manual
THIS STOVE IS DESIGNED TO PROVIDE THE OPTIMUM PROPORTIONS OF FUEL
AND AIR TO THE FIRE IN ORDER TO BURN FREE OF SMOKE AND SOOT. ANY
BLOCKAGE OF THE AIR SUPPLY TO OR FROM THE STOVE WILL SERIOUSLY
DECREASE ITS PERFORMANCE AND WILL BE EVIDENT BY A SMOKING EXHAUST,
A SOOT BUILDUP ON THE WINDOW AND ON OUTSIDE WALLS. FOR BEST
OPERATION, THE ASH CONTENT OF THE PELLET FUEL SHOULD BE LESS THAN
1% AND THE CALORIFIC VALUE APPROXIMATELY 8,500 BTU/LB. OTHERS FUELS
WITH A HIGH ASH CONTENT WILL REQUIRE A HIGHER LEVEL OF MAINTENANCE
AND CLEANING.
THE STOVE WILL NOT OPERATE USING NATURAL DRAFT OR WITHOUT A POWER
SOURCE TO ACTIVATE THE BLOWER SYSTEMS AND FUEL FEED SYSTEM.
STOVE BUILDER INTERNATIONAL INC. GRANTS NO WARRANTY, IMPLIED OR
STATED, FOR IMPROPER INSTALLATION OR LACK OF MAINTENANCE OF YOUR
STOVE, AND ASSUMES NO RESPONSIBILITY OF ANY CONSEQUENTIAL
DAMAGES.
IF YOU NOTICE A SMOLDERING FIRE (BURNPOT FULL BUT NO VISIBLE FLAME)
AND A HEAVY SMOKE BUILDUP IN FIREBOX, IMMEDIATELY TURN OFF THE
STOVE, BUT DO NOT UNPLUG IT. DO NOT OPEN THE DOOR OR THE HOPPER LID.
MAKE SURE THAT THE FRESH AIR INTAKE SHUTTER WORKS FREELY. WAIT
UNTIL SMOKE INSIDE THE FIREBOX CLEARS AND BLOWERS SHUT DOWN. DO AS
INSTRUCTED IN “EVERYDAY STARTUP” THEN ATTEMPT TO RESTART THE
STOVE. IF THE PROBLEM PERSISTS, CONTACT YOUR DEALER. NOTE THAT
SMOKE BUILD-UP DURING IGNITION MAY OCCUR. SMOKE CAN ACCUMULATE IN
THE FIREBOX FOR A FEW SECONDS JUST BEFORE THE IGNITOR IS HOT
ENOUGH TO FIRE-UP THE PELLETS IN THE BURN POT. THIS IS NORMAL. AS
SOON AS THERE IS FIRE IN THE BURN POT, SMOKE WILL DISAPPEAR.
MAINTAIN PROPER VENTILATION. IT IS IMPORTANT THAT ADEQUATE OXYGEN IS
BEING SUPPLIED TO THE FIRE FOR PROPER COMBUSTION. DURING THE WINTER
SEASON, MAKE SURE THAT THE FRESH AIR INTAKE IS FREE OF ANY ICE, SNOW,
ETC., AS THIS WILL STARVE THE FIRE OF AIR AND PREVENT THE PROPER
OPERATION OF THE STOVE. MAKE SURE THE FRESH AIR INTAKE BACKDRAFT
SHUTTER WORKS FREELY.
OPERATING YOUR STOVE AT THE MAXIMUM SETTING DURING A LONG PERIOD
OF TIME MAY REDUCE THE STOVE AND ITS COMPONENTS LIFE EXPECTANCY.
5.1.1 Zone Heating and How to Make It Work for You
Your new pellet stove is a space heater, which means it is intended to heat the area it is
installed in, as well as spaces that connect to that area, although to a lower temperature. This
is called zone heating and it is an increasingly popular way to heat homes or spaces within
homes.
Zone heating can be used to supplement another heating system by heating a particular
space within a home, such as a basement family room or an addition that lacks another heat
source.
Summary of Contents for Euromax EP00070
Page 64: ...64 Euromax Pellet Stove Installation and Operation Manual 10 Wiring Diagram ...
Page 77: ...Euromax Pellet Stove Installation and Operation Manual 77 SECTION B ...
Page 78: ...78 Euromax Pellet Stove Installation and Operation Manual SECTION C ...
Page 79: ...Euromax Pellet Stove Installation and Operation Manual 79 SECTION D SECTION E ...
Page 80: ...80 Euromax Pellet Stove Installation and Operation Manual SECTION F SECTION G ...
Page 81: ...Euromax Pellet Stove Installation and Operation Manual 81 SECTION H SECTION I ...
Page 82: ...82 Euromax Pellet Stove Installation and Operation Manual SECTION J SECTION K ...