4. Electrical installation

4.1 General

DANGER

Turn off electrical power before servicing.  

Contact with live electric components can cause shock or death.

All electrical wiring must be in accordance with requirements of authority having jurisdiction or, in absence of such

 

re-

quirements, with National Electrical Code NFPA 70 — latest edition.

 

If an external electrical source is utilized,

 

system must 

be electrically grounded in accordance with requirements of the authority having jurisdiction or, in the

 

absence of such 

requirements, with the National Electrical Code NFPA 70 — latest edition.

 

 

Power requirements for the system depends on the fan size. Electrical requirements are:

 

y

RSHT009

 

1 x 120 V/60 Hz

 

0.85 Amps

 

y

RSHT012

 

1 x 120 V/60 Hz

 

1.25 Amps

 

y

RSHT014

 

1 x 120 V/60 Hz

 

3.50 Amps

 

y

RSHT016

 

1 x 120 V/60 Hz

 

4.50 Amps 

The 

exodraft

 chimney fans have a split capacitor motor with infinitely variable speed. 

The fan speed control supplied is rated 1 x 120 V/60 Hz and 5 Amps.

 

It has an adjustable low voltage set point 

of min.

 

65 V +/- 5 V.

 

NOTICE

If any of the original wire supplied with the system must be replaced, use similar wire of the same 

temperature rating. Otherwise, insulation may melt or degrade, exposing bare wire.

4.2 Connection and wiring diagram for single fan with fan speed control

The wiring diagram below shows the wiring of the chimney fan and how it is connected to the fan speed control.

Junction 

box

FSC, fan 

Speed contro

l

Chimney fan

 

RED 

WHITE 

BLACK 

GREEN 

FAN 

MOTOR 

120/1/60 

NOTES: 

 

      THE DISCONNECT MEANS AND CIRCUIT PROTECTION ARE TO 

      BE PROVIDED BY THE INSTALLER OF THIS DEVICE 
       

All wiring must be in 

flexible or rigid metal 

conduit 

LEGEND: 

    

24 VAC 

   120 VAC 

WEA

THERPROOF BO

 

 

FAN SPEED  

CONTROL 

9

3100153 RSHT009 - 016 2012-11-15

Summary of Contents for RSHT009-016

Page 1: ...formation Chapters 1 2 Mechanical installation Chapter 3 Electrical installation Chapter 4 Start up and configuration Chapter 5 Maintenance and troubleshooting Chapter 6 READ AND SAVE THESE INSTRUCTIO...

Page 2: ...g eration and Air Conditioning Engineers ASHRAE and the local code authorities 5 This unit must be grounded How to use this manual This installation manual does not contain any system design documenta...

Page 3: ...must be in accordance with the requirements of authority having jurisdiction or in the absence of such requirements with the National Electrical Code NFPA70 1 2 Shipping The packing list attached to...

Page 4: ...41 9 47 2 kg 11 6 15 2 19 0 21 4 Dimensions A in 11 7 12 8 14 6 15 7 mm 298 325 372 400 B x B in 11 7 14 3 16 6 18 8 mm 296 364 422 478 C in 10 8 13 5 15 6 17 4 mm 275 344 395 441 D in 3 0 3 3 3 9 3...

Page 5: ...the fan should be secured by wires attached on the chim ney and on the roof at 2 to 3 different points Brick chimneys usually do not need any kind of support to carry the weight of the chimney fan Sy...

Page 6: ...must be removed The steel chimney adapter SCA slides right into the chimney where the long collar engage ment ensures safe anchoring If necessary the adapter can be secured by means of long self tappi...

Page 7: ...s must be sealed with silicone CAUTION Under conditions with extremely strong winds surrounding the top of the chimney the chimney fan must be secured by steel wires supplied with the fan 3 4 Single f...

Page 8: ...4 GA or thicker y y When installing multiple fans it is extremely important that the fans are of the same model and size and they must be controlled in tandem by one 1 motor speed control 3 6 Multiple...

Page 9: ...Hz 3 50 Amps y y RSHT016 1 x 120 V 60 Hz 4 50 Amps The exodraft chimney fans have a split capacitor motor with infinitely variable speed The fan speed control supplied is rated 1 x 120 V 60 Hz and 5 A...

Page 10: ...N FAN MOTOR WEATHERPROOF BOX WEATHERPROOF BOX L 4 4 Connection and wiring diagram for single fan with EFC211 The diagrams below show the wiring of a single chimney fan when used in conjunction with an...

Page 11: ...Most pizza ovens consist of a dome with a front opening that can be closed with a cast iron door Above the opening a hood connected to the flue as sures smoke and odors are collected and removed safel...

Page 12: ...iod of time CAUTION Do not over fire the fireplace stove or pizza oven Small deposits of creosote could be ignited and start a small chimney fire which could cause the chimney flue to reach a dangerou...

Page 13: ...g out D Unscrew and remove the 1 4 bolt at the end of the vane pipe axle A B C D E Use a 3 8 bolt min length 5 5 to draw the wheel of the motor axle E Replace Motor F Loosen the cable gland G Remove t...

Page 14: ...an speed control is off Bad electrical connections Check the circuit breaker Turn fan speed control on Check and correct problem There is power to the fan but it is not operating Bad electrical connec...

Page 15: ...Notes 15 3100153 RSHT009 016 2012 11 15...

Page 16: ...SA Canada ENERVEX Inc 1685 Bluegrass Lake Parkway Alpharetta GA 30004 P 770 587 3238 F 770 587 4731 T 800 255 2923 info enervex com www enervex com www exodraft com Volko Supply www chimneyfansource c...

Reviews: