PROFInet Module
SINUS H
25
/
34
The inverter’s output torque. Torque is expressed in percentages (%), and can be increased or
decreased by 0.1%.
Torque value is displayed correctly only if the inverter’s control mode is set to “Sensorless”
or “Vector.”
7.2.7
Current
The inverter’s output current. Current is expressed in amperes (A), and can be increased or decreased
by 0.1 A.
7.2.8
Dummy
Not used
8
Supported PROFIdrive Parameters
Parameters
PNU
R/W
Description
922
R
Displays the selected PROFIdrive Cyclic Telegram
type.
1 → Standard Telegram
100 → Vendor Specific Telegram
* This parameter does not support writing via
PROFIdrive protocol. Set this parameter using the
inverter keypad. Go to COM 22 “opt para-13,” and set
it to “0” to select “Standard Telegram,” and to “1” to
select “Vendor Specific Telegram.”
944
R
Fault message counter
The parameter value increases by 1 each time a fault
condition occurs. The controller, such as a PLC, on the
PROFInet is notified of the inverter’s fault condition by
this parameter.
947
R
Fault number
* Refer to
<9 Fault Message Counter (PNU[944]) and
.
953
R
Warning word
* Displays the “Warning information” parameter value at
communication address 0h0334.
964
R
An array of five 16-bit word values that expresses the
Sinus H communication module information.
0: Manufacturer (the PROFInet vendor ID “849”, as
defined by the Profibus.org, is displayed (referenced
from communication address 0h351).
1.
Device Type: “1” is displayed for Sinus H PROFInet