46
Enertech Global
IOM, ZS/ZT Models
SECTION 8: SOFT START CONTROLS
Specifications are subject to change without notice (03.09.2014)
5
RSBS2332A2V22C24SM28, RSBS2325A2V22C17SM29
Mode of Operation
1. Applicable when current limit is 45 AACrms
2. Safety of household and similar electrical appliances. Particular requirements for electrical heatpumps, airconditioners and dehumidifiers.
3. Auxiliary relay terminal (available on RSBS23..A2V22C24) is not suitable to be connected to accessible SELV circuits.
4. Refer to voltage dips and interruptions section for mode of operation.
Approvals
UL (E172877), cUL
CE Marking
LVD IEC/ EN 60947-4-2/ EN60335-1/
EN 60335-2-40
2,3
EMC : Immunity
IEC/ EN 61000-6-1, EN 55014-2
Emission
IEC/ EN 55014-1
IEC/ EN 61000-3-11, IEC/ EN 61000-3-12
Electrostatic Discharge ESD
Immunity
IEC/ EN 61000-4-2
8kV, PC2 air discharge
Electrical fast transient/
4kV, PC2 contact
Burst Immunity
IEC/ EN 61000-4-4
Output
2kV, PC2
Input
1kV, PC2
Electrical Surge Immunity
IEC/ EN 61000-4-5, PC2
Output, line to line
1kV
Output, line to earth
2kV
Input, line to line
500V
Input, line to earth
1kV
Radiated Radio Frequency
EN 61000-4-3, PC1
3V/m, 80-2700MHz
Conducted radio-frequency
immunity
IEC/ EN 61000-4-6, PC1
3V/m, 0.15-80MHz
Voltage dips & interruptions
4
IEC/ EN 61000-4-11
Continuous disturbance
IEC/ EN 55014-1
1
Radio interference voltage
emissions (conducted)
CISPR 11
IEC/ EN 55011, Class B
1
Disturbance power
CISPR 14
IEC/ EN 55014-1
1
Harmonics
IEC/ EN 61000-3-2
1
IEC/ EN 61000-3-12
1
Flicker
IEC/ EN 61000-3-11
1
(Load Conditions apply)
Standards
Normal Condition (Note 3)
6 min.
3 min.
Mains Operational Voltage
Green LED
Control Voltage
Controller Output
Orange LED
Undervoltage Condition (Note 4)
1 sec
0.5 sec 0.5 sec
Mains Operational Voltage
Green LED
Control Voltage
Controller Output
Alarm indication, Red LED
Line voltage <190 VAC for < 1 sec.
Line voltage <190 VAC for 1 sec.
Sottotensione (Note 4)
Mains Operational Voltage
Green LED
Control Voltage
Controller Output
Alarm indication, Red LED
Line voltage <180 VAC for < 1 sec.
Line voltage <180 VAC for
≥
1 sec.
Mode of Operation