background image

2

Important information

2

Care for your safety

2

Unpacking

2

Storage

3

Installation

3

Cell strings connected in
parallel

3

Charging

4

Discharging

4

Technical specifications of bloc

6

Typical assembly drawing

6

Battery record sheet

7

Important information

Please read this manual immediately on

receipt of the battery before commencing

unpacking and installing. Failure to comply

with these instructions will render any

warranties null and void.

Care for your safety

No smoking, no naked flames,

no sparks

Electrolyte is corrosive

Electrical hazard

Shield eyes

Clean all acid splash in eyes or
on skin with plenty of clean
water. Then seek medical help.
Acid on clothing is to be
washed with water.

Danger

Read instructions

Risk of explosion or fire. Avoid
any short circuit.  Metallic parts
under voltage on the battery, do
not place tools or items on top of
the battery.

Re-cycle scrap
batteries.
Contains lead

Unpacking

It is advisable to unpack the monoblocs

and accessories before commencing

assembly and erection and not to unpack

and erect monobloc by monobloc.

All monobloc/units should be handled

carefully as the plastic container can be

damaged or broken if dropped. Under no

circumstances should the batteries be

lifted by their terminal pillars.

All items should be carefully checked

against the accompanying advice notes to

ascertain if any are missing or damaged.

In this event contact your Enersys

representative.

Handling

PowerSafe VX batteries are
supplied in a fully charged
state and must be unpacked
carefully to avoid very high
short-circuit currents between
terminals of opposite polarity. 

Keep flames away

In case of accidental
overcharge a flammable gas
may be emitted from the
safety vent.

Discharge any possible static
electricity from clothes by
touching an earth connected
part.

Tools

Use tools with insulated
handles.

Do not place or drop metal
objects on the battery.

Remove rings, wristwatch and
articles of clothing with metal
parts that may come into
contact with the battery
terminals.

Publication No: EN-VX-IOM-001  February 03

www.enersysinc.com

Summary of Contents for PowerSafe VX

Page 1: ...Installation Operations and Maintenance Instructions Publication No EN VX IOM 001 February 03...

Page 2: ...unpack the monoblocs and accessories before commencing assembly and erection and not to unpack and erect monobloc by monobloc All monobloc units should be handled carefully as the plastic container c...

Page 3: ...eration gas recombination efficiency 95 Batteries must be installed in accordance with national standards for instance EN 50272 2 otherwise in accordance with the manufacturer s instructions Please no...

Page 4: ...per cell 0 C 2 33 2 36V 10 C 2 30 2 33V 20 C 2 27 2 30V 25 C 2 25 2 28V 30 C 2 24 2 27V 35 C 2 22 2 25V 40 C 2 21 2 24V 45 C 2 19 2 22V 50 C 2 18 2 21V If the charger does not permit an adjustment of...

Page 5: ...g must be carried out with a damp cotton cloth only Check monthly that total voltage at battery terminals is N x 2 28 V for a temperature at 20 C N the number of cells in the battery Take annual readi...

Page 6: ...ical specifications of bloc All dimensions in millimetres Item No Description Cat No 1 Fastener set M6 2 Inter unit connector SUB5176 3 Inter tier connector 35 mm2 max 4 Insulating terminal cover SPH0...

Page 7: ...28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94...

Page 8: ...ters P O Box 14145 Reading PA 196212 4145 USA Tel 1 610 208 1991 1 800 538 3627 Fax 1 610 372 8613 EnerSys EMEA Houtweg 26 1140 Brussels Belgium Tel 32 0 2 247 94 47 Fax 32 0 2 247 94 49 EnerSys Asia...

Reviews: