Works Order No:

Customer Ref:

Installed At:

Battery Type:

No. of Monoblocs:

Date Installed:

Battery Float Voltage:                      V

Ambient Temperature:                                                                                     °C

Battery Charging Current:                A

Average Vpc:

Comments:

Engineer in Charge:

Date of Service:

Volts

per

cell

Volts

per

Monobloc

Volts

per

cell

Volts

per

Monobloc

Volts

per

cell

Volts

per

Monobloc

Volts

per

cell

Volts

per

Monobloc

Volts

per

cell

Volts

per

Monobloc

Volts

per

cell

Volts

per

Monobloc

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

146

147

148

149

150

151

152

153

154

155

156

157

158

159

160

161

162

163

164

165

166

167

168

169

170

171

172

173

174

175

176

177

178

179

180

181

182

183

184

185

186

187

188

189

190

191

192

193

194

195

196

197

198

Battery record sheet

Publication No: EN-VX-IOM-001  February 03

www.enersysinc.com

Summary of Contents for PowerSafe VX

Page 1: ...Installation Operations and Maintenance Instructions Publication No EN VX IOM 001 February 03...

Page 2: ...unpack the monoblocs and accessories before commencing assembly and erection and not to unpack and erect monobloc by monobloc All monobloc units should be handled carefully as the plastic container c...

Page 3: ...eration gas recombination efficiency 95 Batteries must be installed in accordance with national standards for instance EN 50272 2 otherwise in accordance with the manufacturer s instructions Please no...

Page 4: ...per cell 0 C 2 33 2 36V 10 C 2 30 2 33V 20 C 2 27 2 30V 25 C 2 25 2 28V 30 C 2 24 2 27V 35 C 2 22 2 25V 40 C 2 21 2 24V 45 C 2 19 2 22V 50 C 2 18 2 21V If the charger does not permit an adjustment of...

Page 5: ...g must be carried out with a damp cotton cloth only Check monthly that total voltage at battery terminals is N x 2 28 V for a temperature at 20 C N the number of cells in the battery Take annual readi...

Page 6: ...ical specifications of bloc All dimensions in millimetres Item No Description Cat No 1 Fastener set M6 2 Inter unit connector SUB5176 3 Inter tier connector 35 mm2 max 4 Insulating terminal cover SPH0...

Page 7: ...28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94...

Page 8: ...ters P O Box 14145 Reading PA 196212 4145 USA Tel 1 610 208 1991 1 800 538 3627 Fax 1 610 372 8613 EnerSys EMEA Houtweg 26 1140 Brussels Belgium Tel 32 0 2 247 94 47 Fax 32 0 2 247 94 49 EnerSys Asia...

Reviews: