background image

1.  Pass the 120-volt supply wires through 

the center hole in the ceiling mounting 

plate as shown in Figure 10.

2.  Install the ceiling mounting plate on 

the outlet box, by sliding the mounting 

plate over the two screws provided with 

the outlet box (Figure 10). When using 

close-to-ceiling mounting, it is important 

that the mounting plate be level. If 

necessary, use leveling washers (not 

included) between the mounting plate 

and  the  outlet  box.  Note  that  the  flat 

side of the mounting plate is toward the 

outlet box (Figure 10).

3.  Securely tighten the two mounting 

screws.

4.  Carefully lift the assembly up to the 

ceiling mounting plate and hang the fan 

on the hook provided by utilizing one of 

the holes at the outer rim of the ceiling 

canopy (Figure 11). If using standard 

UL Listed

Outlet Box

Outlet Box)

Figure 11

Figure 10

THE HOOK AS SHOWN IN FIGURE 11 IS ONLY 

TO BALANCE FAN WHILE ATTACHING WIRING. 

FAILURE TO HANG AS SHOWN IN FIGURE 11 

MAY RESULT IN HOOK BREAKING, CAUSING 

THE FAN TO FALL. HOOK MUST PASS FROM 

INSIDE TO OUTSIDE OF CANOPY.

WHEN USING THE STANDARD BALL/

DOWNROD MOUNTING, THE TAB IN THE RING 

AT THE BOTTOM OF THE MOUNTING PLATE 

MUST REST IN THE GROOVE OF THE HANGER 

BALL FAILURE TO PROPERLY SEAT TAB IN 

THE GROOVE COULD CAUSE DAMAGE TO THE 

WIRING. 

TO REDUCE RISK OF FIRE OR ELECTRIC 

SHOCK, DO NOT USE A SOLID STATE 

SPEED CONTROL WITH THIS FAN. IT WILL 

PERMANENTLY DAMAGE THE ELECTRONIC 

CIRCUITRY.

6.

Making the Electrical 

Connections

REMEMBER to disconnect the power. If 

you feel you do not have enough electrical 

wiring knowledge or experience, have your 

fan installed by a licensed electrician. 

Follow the steps below to connect the fan 

to your household wiring. Use the wire 

connecting nuts supplied with your fan. 

Secure the connectors with electrical tape. 

Make sure there are no loose strands or 

connections.

WHEN MOUNTING THE FAN ON A SLOPED 

CEILING, THE STANDARD BALL/DOWNROD 

MOUNTING METHOD MUST BE USED. MAKE 

SURE THE MOUNTING PLATE SLOTS ARE ON 

THE LOWER SIDE BY SLIDING THE MOUNTING 

PLATE FROM THE TOP DOWN.

Installing Fan to the 

Electrical Box

mounting, seat the hanger ball in the 

mounting plate socket. Make sure the 

tab on the mounting plate socket is 

properly seated in the groove in the 

hanger ball (Figure 11).

Installing Fan to the 

Electrical Box

Summary of Contents for 355-5952

Page 1: ...52 Energy Select Ceiling Fan Owner s Manual Ventilador de Techo de 132 1cm Manual del Propietario SKU 355 5952 LISTED...

Page 2: ...missing parts or questions regarding installation Please reference your SKU 355 5952 white or UPC 082392 636012 white Safety Rules 1 Unpacking Your Fan 2 Installing Your Fan 3 Operating Your Fan 10 C...

Page 3: ...se water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After making electrical connections spliced conductors shoul...

Page 4: ...r e Blade Attachment Hardware 15 screws 6 Blade Brackets 5 1 Slide On Mounting Plate inside canopy 2 Canopy 3 Downrod and Hanger Ball Assembly 4 Fan Motor Assembly 5 Blades 5 2 Unpacking Your Fan IMPO...

Page 5: ...may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceil ing The maximum angle allowable is 30 If the canopy touches down rod remove the decorative canopy b...

Page 6: ...installation using the downrod with ball and socket mounting and the close to ceiling mounting The close to ceiling mounting is recommended in rooms with less than 8 foot ceilings or in areas where a...

Page 7: ...8 Close to Ceiling Mounting 1 Remove the mounting plate from the canopy by loosening the four screws on the top of the canopy Remove the two non slotted screws and loosen the slotted screws This will...

Page 8: ...WHEN USING THE STANDARD BALL DOWNROD MOUNTING THE TAB IN THE RING AT THE BOTTOM OF THE MOUNTING PLATE MUST REST IN THE GROOVE OF THE HANGER BALL FAILURE TO PROPERLY SEAT TAB IN THE GROOVE COULD CAUSE...

Page 9: ...ing plate since the ball downrod assembly is not used 2 Connect the fan motor white wire to the supply white neutral wire using a wire nut Figure 12 3 Connect the fan motor black wire to the supply bl...

Page 10: ...firmly 2 Install the remaining two mounting screws into the holes in the canopy and tighten firmly 3 You may now proceed to attaching the fan blades CLOSE TO CEILING MOUNTING 1 Carefully unhook the f...

Page 11: ...e caused when blade levels are unequal Check this level by selecting a point on the ceil ing above the tip of one of the blades Measure from a point on the center of each blade to the point on the cei...

Page 12: ...re 16 Figure 17 WAIT FOR THE FAN TO STOP BEFORE REVERSING THE DIRECTION OF BLADE ROTATION Warm weather Forward A down ward air flow creates a cooling effect as shown in Figure 16 This allows you to se...

Page 13: ...led ball bearings MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BE FORE YOU ATTEMPT TO MAKE ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy...

Page 14: ...e used by the light kit FAN SIZE SPEED VOLTS AIRFLOW CFM FAN POWER CONSUMPTION WITHOUT LIGHTS WATTS AIRFLOW EFFICIENCY Higher is Better CFM watt NET WEIGHT GROSS WEIGHT CUBE FEET 52 Low 120 1520 8 9 5...

Page 15: ...al and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty The manufacturer hereby disclaims any and all...

Page 16: ...o cuestiones relacionadas con la instalaci n Por favor usa como referencia el N de SKU 355 5952 blanco o UPC 082392 636012 blanco Normas de seguridad 1 C mo desempacar el ventilador 2 C mo instalar el...

Page 17: ...r el ventilador o las aspas En general a la hora de limpiar bastar con usar un pa o seco o ligeramente humedecido 11 Despu s de concluir con las conexiones el ctricas debes voltear los conductores emp...

Page 18: ...e Herrajes de montaje de aspas 15 tornillos 5 Aspas 5 6 Soportes del aspa 5 1 Placa de montaje deslizante dentro de la cubierta 2 Cubierta 3 Ensamblado de tubo bajante y bola 4 Ensamblado del motor d...

Page 19: ...Nota Tal vez necesites un tubo bajante m s largo para mantener la altura m nima adecuada de las aspas al instalar el ventilador en un techo inclinado El ngulo m ximo permitido es de 30 Si la cubierta...

Page 20: ...ntilador RECUERDA desconectar la corriente Sigue estos pasos para colgar correctamente tu ventilador NOTA Este ventilador de techo viene con dos tipos de ensamblados de soporte la instalaci n de techo...

Page 21: ...ca de montaje de la cubierta aflojando los cuatro tornillos de la parte superior de la misma Quita los dos tornillos sin ranura y afloja los tornillos ranurados Esto te permitir retirar la placa de mo...

Page 22: ...cabeza de los tornillos Figura 11 Figura 10 6 C mo instalar el ventilador en la caja el ctrica usando uno de los orificios en el borde exterior de la cubierta de techo Figura 11 Si usas el montaje es...

Page 23: ...ensamblado de tubo bajante y bola 2 Conecta el cable blanco del motor del ventilador al cable blanco de suministro neutro usando una tuerca de cable Figura 12 3 Conecta el cable negro del motor del v...

Page 24: ...ranuras de cierre de la cubierta del techo con los dos tornillos de la placa de montaje Alza para enganchar las ranuras y gira de izquierda a derecha Aspa Tornillos Soporte de aspas Ranura Poste de a...

Page 25: ...problemas de oscilaci n del ventilador se deben a que las aspas no est n a un mismo nivel Verifica este nivel seleccionando un punto en el techo sobre la punta de una de las aspas Mide desde un punto...

Page 26: ...6 Figura 17 ESPERA A QUE SE DETENGA EL VENTILADOR ANTES DE INVERTIR LA DIRECCI N DE GIRO DE LAS ASPAS Clima c lido Hacia adelante Un flujo de aire hacia abajo crea un efecto refrescante como se muestr...

Page 27: ...erifica fusibles o disyuntores principales y secundarios 2 PRECAUCI N Aseg rate de que est desactivada la electricidad principal Verifica conexiones de cables en l nea al ventilador y conexiones de ca...

Page 28: ...O VELOCIDAD VOLTIOS FLUJO DE AIRE PIES CUAD X MIN CONSUMO DE ENERG A DEL VENTILADOR SIN LAS L MPARAS EN VATIOS EFICIENCIA DE FLUJO DE AIRE MIENTRAS M S ALTA MEJOR PIES C B X MIN VATIOS PESO NETO PESO...

Page 29: ...ticas cambiantes Es normal cierta oscilaci n y no se considerar una falla Cualquier servicio t cnico conducido por personas no autorizadas anular la garant a No hay ninguna otra garant a expresa Media...

Reviews: