Replacing Your Catalytic Combustor 

Visually inspect the catalytic combustor at 
least three times during the heating season to 
determine if physical deterioration has 
occurred.  Only replace the combustor if it is 
damaged or no longer operating and use only 
Applied Ceramics Combustors. (See Applied 
Ceramics Warranty for information on 
replacement.) 

Figure 16 

 
The Energy King fireplace has two catalytic 
combustors. To replace combustors, look up 
inside the stove and locate the catalytic 
combustor retainer plate with holes across its 
surface. Remove the bolts on each side of 
the plate and remove the plate. Next, remove 
the catalytic combustors. Position the 
replacement catalytic combustors snugly and 
replace the retainer plate, tightly bolting the 
plate on both sides. 

Rev 06/2007 

15

Summary of Contents for Silhouette 2800

Page 1: ...SILHOUETTE 2800 2850C Zero Clearance Wood Fireplace Installation and Operation Manual RJM Manufacturing Inc P O Box 27 1875 Olson Drive Chippewa Falls WI 54729 715 720 1794 Fax 715 720 1797...

Page 2: ...ireplace is designed for a lifetime of durable reliable performance and easy operation This manual describes the installation and operation of your Energy King factory built fireplace Be sure to read...

Page 3: ...top 10 TYPES OF WOOD 10 WARNINGS 11 INITIAL FIRE 12 STARTING A FIRE MODEL 2800 12 OPERATING SILHOUETTE MODEL 2850C 13 What is a Catalytic Woodstove 13 Using a Catalytic Woodstove 13 Troubleshooting th...

Page 4: ...and cleaned regularly A High Temperature Listed Chimney is required 8 Do not connect your solid fuel appliance to a chimney flue already venting another appliance 9 Dispose of cool ashes with care Sto...

Page 5: ...e thermostatically controlled blower has manual and automatic controls see Figure 6 Lower Grill Provides access to blower draft control and ash pan Keep area accessible This grill also allows cool air...

Page 6: ...st be in the fireplace at all times when in operation Without this damage will occur Next insert the D brick 9 x 4 x 1 in the brick baffle The bricks are held in place by a slot in the back of the fir...

Page 7: ...an optional 200CFM Blower This can be installed by lowering the grill and placing the blower under the firebox on the right side A tie strap is provided to clamp the blower assembly in place Make sur...

Page 8: ...ilt fireplace on a combustible floor is approved as long as an area extending 16 in front of and 8 to each side of the fuel opening is protected Insulate this area with non asbestos millboard or equiv...

Page 9: ...l To Mantel Optional Remote Outlet Grills from Ceiling Faceplate to Sidewall Duct Boots to Framing Side Wallboard to Faceplate Edge Perimeter 0 0 2 0 0 11 11 8 2 1 0 Unit Height Unit Width Unit Depth...

Page 10: ...e sides and back are 0 clearance to combustibles from the standoffs and open from the top of the unit to the ceiling Do not remove standoffs from the units Studs and sheeting must be kept 0 from these...

Page 11: ...he first 2 x 4 on edge with the second 2 x 4 laying flat The studs are placed vertically over the header working from the center of the fireplace outward space first stud 8 from the center This will g...

Page 12: ...e and 2 above any obstructions within 10 see Figure 14 below The minimum draft of the fireplace is 06 of water column A straight chimney is best Up to two 30 degree elbows can be used for offsets Figu...

Page 13: ...woods such as ash beech birch maple and oak are denser and provide a longer lasting fire Season your wood Allow wood to dry out reducing water content in wood for at least one year Purchase or cut woo...

Page 14: ...he fireplace door is closed check for the following causes 1 Proper draft has not had time to establish Open draft control 2 Blockage in the fireplace stovepipe or chimney 3 Leaks in the chimney 4 Col...

Page 15: ...per on the firebox floor and cover with dry kindling Open the draft control completely and light the fire Draft control is located above the glass door After a fire is established add more dry wood an...

Page 16: ...ll rod Your Energy King stove is equipped with a bypass mechanism located above the door The bypass allows you to bypass the smoke around the combustor when you do not have the necessary 500 degrees t...

Page 17: ...Burn only dry seasoned wood Lightly brush the the catalyst such as heavy papers wet face of the combustor with a soft bristle brush wood garbage etc such as a paintbrush to remove the accumulation The...

Page 18: ...pplied Ceramics Warranty for information on replacement Figure 16 The Energy King fireplace has two catalytic combustors To replace combustors look up inside the stove and locate the catalytic combust...

Page 19: ...ve gas temperatures reach 600 degrees F within two or three minutes after a fire is started if the fire is allowed to die down immediately it may go out or the combustor may stop working Once the comb...

Page 20: ...on t touch the glass In case of breakage glass must be replaced with a high temperature glass such as Robax Tempered or ordinary glass will not withstand the high temperatures of the Energy King firep...

Page 21: ...clean soft surface such as a towel Find the ends of the gasket and pull it off Take a screwdriver and remove excess gasket glue from the channel Take new stove gasket cement available at your local w...

Page 22: ...plicable Unit does not give off enough heat Is the unit installed correctly 1 Check to see if the unit has an adequate cold air return or inadequate hot air outlet 2 Room may be too airtight inadequat...

Page 23: ...tatic pressure too low Check and correct system 5 Thermostat is not opening damper or turning on forced draft fan a Check wall thermostat b Check the thermostat wires possible short or broken wire c C...

Page 24: ...ican Heritage Dictionary Second College Edition Cat a lyst n 1 Chem A substance usually present in small amounts relative to reactants that modifies and especially increases the rate of a chemical rea...

Page 25: ...ires more heat restart the fire with kindling as always but add smaller fuel loads This allows your stove to operate at maximum efficiency and with minimum emissions Avoid the temptation of building a...

Page 26: ...thing I should consider R The woodstove and chimney work as a system It is important that the stove s chimney system be sized properly according to the manufacturer s instructions Whether venting int...

Page 27: ...red by this warranty This limited warranty does not apply If your appliance has not been installed operated and maintained in strict accordance with instructions provided in the Installation Operation...

Page 28: ...Y KING dealer in your area contact RJM Manufacturing Inc directly Provide your name address phone number serial number and model number of the Fireplace date of purchase name and address of installer...

Page 29: ...replacement at the following special price schedule Year 4 85 00 Year 5 95 00 Year 6 105 00 Year 7 and after at current retail price Conditions 1 2 and 3 also apply to the Prorated portion of the warr...

Reviews: