6
Economy Control Switch (EcoMode)
Turning EcoMode to ON is recommended for minimizing fuel consumption. In this
mode the engine will dynamically meet the demand of the current electrical load
and will automatically go into an idle state if all electrical loads are disconnected.
Before connecting or removing a high load device to the generator, turn EcoMode
to OFF until that device has reached running power.
When EcoMode is OFF, the engine runs at full speed.
Display Button
Press the DISPLAY button once to turn on the backlight. The hourmeter will be
shown, and the backlight will turn off after 10 seconds. Press the DISPLAY button
multiple times to cycle through different information displays.
Reset Button
Use the RESET button in the case of a sudden engine shutdown resulting from
prolonged engine overload.
Disconnect all electrical appliances and then press and hold the reset button for 1
second, this will restart the engine. After restarting, if the overload indicator light has
turned off and the output indicator light has turned back on, reconnect the electrical
appliances. Otherwise, stop the engine by turning the power switch to STOP, and
check the generator.
If the generator is running normally, the RESET button will have no effect.
NOTE
■
The RESET button is available a maximum of 5 times for every full start of the
generator. Shut down the generator and restart using the power switch to
refresh the restart times.
AC Circuit Breakers
While the generator is running, the breakers should be put in the ON position.
If the current has exceeded its limits it will automatically pop out to the OFF
position. Reduce the electrical load on the generator and push the button back to
the ON position.