background image

34

NOTE: 

Relative humidity 60% correction factor C-0.01
Relative humidity 80% correction factor C -0.02
Relative humidity 90% correction factor C-0.03
Relative humidity 100% correction factor C-0.04

Example:

Rated power ( P

N

 ) 2.8kVA generator (Altitude: 1000m) Ambient temperature: 35°C, 

Relative humidity: 80%

P=Pn*(C-0.02)=2.8*(0.82-0.02)=2.24kVA

Altitude (m)

Ambient Temperature°C 

25

30

35

40

45

0

1

0.98

0.96

0.93

0.90

500

0.93

0.91

0.89

0.87

0.84

1000

0.87

0.85

0.82

0.80

0.78

2000

0.75

0.73

0.71

0.69

0.66

3000

0.64

0.62

0.60

0.58

0.56

4000

0.54

0.52

0.50

0.48

0.46

12.1) Environment Correction

The standard condition of rated power output:

Altitude: 0m
Ambient temperature: 25

°

C

Relative humidity: 30%

Factor of Environment Correction:

12. APPENDIX 

Summary of Contents for eZV3200

Page 1: ...eZV3200 USER GUIDE...

Page 2: ...tain graphic designs are trademarks of Energizer Brands LLC and related subsidiaries and are used under license by Midland Power Inc All other brand names are trademarks of their respective owners Nei...

Page 3: ...Thanks for choosing the EZV Series You re excited to power up so we ll keep this brief Let s get started...

Page 4: ......

Page 5: ...ators com or visit us online at www energizergenerators com IMPORTANT SAFETY INSTRUCTIONS This user guide contains important instructions for your product that should be followed during installation a...

Page 6: ...Operation Check Checking the Oil Level 8 Checking the Fuel Level 9 Checking the Air Filter 10 4 Starting the Engine Carburetor Modification for High Altitude Operation 13 5 Generator Use Output Overlo...

Page 7: ...rgenerators com 1 877 528 3772 support energizergenerators com www energizergenerators com See page 35 for more information Product registration is required for all product support and warranty covera...

Page 8: ......

Page 9: ...eration due to risk of burns Pay attention to the warning labels The engine exhaust system will become heated during operation and remain hot immediately after the engine is stopped Gasoline is a high...

Page 10: ...nerator shall be connected through transfer equipment that switches all conductors other than the equipment grounding conductor The frame of the generator shall be connected to an approved grounding e...

Page 11: ...ontrol panel before each use Moisture can damage the generator and can lead to an electric shock When storing gasoline or equipment with fuel in tank store away from furnaces stoves water heaters or o...

Page 12: ...4 Folding Handle Control Panel Fuel Gauge Battery Maintenance Panel Wheel Air Filter Maintenance Panel Recoil Grip Oil Maintenance Panel Fuel Cap Rear Handle Muffler 2 COMPONENT IDENTIFICATION...

Page 13: ...6 Digital Display 7 Reset Button 8 Display Button 9 23 3A AC Breaker 10 20A AC Breaker 11 Twist Lock 120V AC Outlet 12 Dual 120V AC Outlet 13 Ground Terminal 14 Output Indicator Light 15 Overload Ind...

Page 14: ...en engine shutdown resulting from prolonged engine overload Disconnect all electrical appliances and then press and hold the reset button for 1 second this will restart the engine After restarting if...

Page 15: ...designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase reaches an unsafe limit the oil alert system will automatically shut do...

Page 16: ...securely Replace the oil maintenance panel and screws NOTE Do not tilt the generator when adding engine oil This could result in overfilling and damage to the engine Using non detergent or 2 stroke oi...

Page 17: ...h Octane 91 or higher Pump Octane 86 or higher Never use stale or contaminated gasoline or an oil gasoline mixture Avoid getting dirt or water into the fuel tank Do not use a mixture of gasoline conta...

Page 18: ...ccess panel Remove the air filter cover 2 Clean the air filter with soap and water or solvent Squeeze dry and then soak in clean engine oil 3 Squeeze out all excess oil and reinstall Replace the filte...

Page 19: ...tor DANGER CARBON MONOXIDE USING A GENERATOR INDOORS WILL KILL YOU IN MINUTES WARNING Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas Breathing car...

Page 20: ...ly be started using the recoil method If there is a battery and it is flat running the generator will recharge the battery A Manual Recoil Start Pull the starting grip slowly until it is engaged then...

Page 21: ...fication for High Altitude Operation At high altitudes the standard carburetor air fuel mixture will be too rich Fuel consumption will increase and performance will decrease A very rich mixture will a...

Page 22: ...f the extension cable 60 meters for cable of 1 5mm2 100 meters for cable of 2 5mm2 Keep away from other electric cables or wires 5 1 Output Overload and Oil Alert Indicator Light Solid Description Gre...

Page 23: ...cable from the negative battery terminals 2 Connect the DC outlet to the battery terminals using the included charging cable Connect red lead to positive battery terminal and black lead to negative b...

Page 24: ...Confirm all electrical appliances are in good working condition before connecting them to the generator If an electrical appliance becomes abnormal sluggish or stops suddenly shut off the generator en...

Page 25: ...the power switch to STOP immediately 1 Switch off the connected electrical appliances and pull out their plugs 2 Turn the power switch to STOP or press the OFF button on the remote control 3 Turn the...

Page 26: ...aust leaks while the engine is running Have all the leaks repaired before continuing operation 3 Check for dirt and debris and clean as necessary 4 Check the engine oil level and add oil as necessary...

Page 27: ...eaning Sediment Cup Cleaning Spark Arrester Cleaning Spark Plug Inspection Cleaning Replacement Valve Clearance Inspection Adjusting Combustion Chamber Inspection Adjusting Fuel Tank and Strainer Clea...

Page 28: ...standards regarding the emission control systems Tune up specifications are provided in the Specifications section and a description of the emission control system may be found in the appendix to thi...

Page 29: ...placement parts other than those from an authorized service centre will void the warranty Air Index Models certified for sale in California An Air Index Information label is applied to engines certifi...

Page 30: ...ing s rubber bung 3 Place oil collection pan under oil drain bolt 4 Remove the oil drain bolt and drain oil into the oil collection pan completely 5 Reinstall the oil drain bolt 6 Refill the oil and c...

Page 31: ...not throw it into the trash or pour it on the ground 7 3 Air Filter Service A dirty air filter will restrict air flow into the carburetor Clean and maintain the air cleaner regularly especially in du...

Page 32: ...the bottom of the spark plug Do not rinse spark plug in water Follow guidelines and be careful not to overtighten the spark plug 1 Remove the spark plug cap 2 Remove the spark plug with the spark plu...

Page 33: ...ugh to damage the engine Never use a spark plug with an improper heat range 7 5 Spark Arrester Maintenance 1 Remove the screws and remove the muffler guard 2 Take off the spark arrester from the muffl...

Page 34: ...res c battery rated capacity If the battery is dead start the generator manually and the battery will charge Replacing the battery 1 Loosen the screws of the battery maintenance cover remove the cover...

Page 35: ...direct sunlight while in an enclosed transport vehicle The high temperature inside the vehicle could cause fuel to vaporize resulting in a possible explosion Drain the generator of fuel and oil befor...

Page 36: ...uretor e Reinstall the spark plug cap 3 Change new oil while engine is still warm from operation 4 Remove the spark plug and pour a tablespoon of clean engine oil 10 20ml into the cylinder Revolve the...

Page 37: ...29 8 3 Draining the Fuel Tank 1 Turn OFF the engine Remove the fuel cap and the debris screen underneath the fuel cap 2 Siphon the fuel into an approved gasoline container...

Page 38: ...n RUN Add the recommended oil Turn the power switch to RUN Clean readjust the gap and dry the spark plug Replace if necessary Is there enough oil in the engine Is the spark plug in good condition Turn...

Page 39: ...fault Check the electrical appliance for any fault Is the DC circuit protector OFF Stop the engine and then replace or repair the appliance Repair or replace the appliance Turn the DC circuit protect...

Page 40: ...NERATOR Model Name EZV3200 Rated Frequency 60Hz Rated Voltage 120V Rated Current 23 3A Rated Speed 3600min 1 Rated Output Power 2 8kVA Max Output Power 3 2kVA OTHER SPECIFICATIONS DC Output 12V 5A Fue...

Page 41: ...x Winding 1 Aux Winding 2 Main Winding Battery 12V7 Ah Ignition Winding Trigger Warning Oil Sensor Spark Plug Ignition Fuse 6A DC Reset Stepper Motor 20A AC Breaker 25A AC Breaker ACTUATOR INVERTER BO...

Page 42: ...ature 35 C Relative humidity 80 P Pn C 0 02 2 8 0 82 0 02 2 24kVA Altitude m Ambient Temperature C 25 30 35 40 45 0 1 0 98 0 96 0 93 0 90 500 0 93 0 91 0 89 0 87 0 84 1000 0 87 0 85 0 82 0 80 0 78 200...

Page 43: ...during the three 3 year period The warranty coverage is continual from the initial date of purchase and does not restart at anytime under any circumstances This limited warranty is valid for residenti...

Page 44: ...rranty we do not have the obligation to bear any transportation fees of any product to from an authorized Warranty Center Unauthorized alteration installation or any cause other than defects in materi...

Page 45: ...lator Intake manifold Evaporative Fuel Tank Fuel Cap Fuel Hoses Vapor Hoses Carbon Canister Canister Mounting Brackets Fuel Strainer Fuel cock Fuel Pump Fuel Hose Joint Canister Purge Hose Joint Exhau...

Page 46: ...ted and mailed You can also register online at www energizergenerators com Once your registration is complete your receipt will be on file and any future warranty claims will be easily created Proof o...

Page 47: ...Enjoy Be sure to check energizergenerators com for updates regarding your generator...

Page 48: ......

Reviews: