colliding and scratching with any cement surface or 
hard  object  such  as  the  ground,  color  steel,  tiles, 
metal corrugated roofing, etc. 

When  the  photovoltaic  modules  are  stacked,  they 
must  be  neatly  and  stably  stacked  on  a  horizontal 
surface, and stacked with the glass side facing down 
and the back side facing up. At the same time, there 
must  be  cardboard  bedding  under  the  photovoltaic 
modules.  For  example,  when  installing  photovoltaic 
modules on the roof, the number of modules stacked 
up  on  a  pile  should  not  exceed  20.  For  roofs  with 
poor  load-bearing  capacity,  it  is  recommended  that 
the  designer  or  installer  evaluate  the  load-bearing 
capacity of the roof and reduce the load-bearing unit 
area of the roof by reducing the number of piles. At 
the same time, avoid placing any installation tools or 
other  objects  on  the  surface  of  the  photovoltaic 
module. 

Energizer

  Solar  PV  modules  adopt  high  and  low 

current  bins,  and  the  handlers  need  to  place  them 
separately and mark them according to the markings 
on the power list of the PV modules outer packaging 
(for  example,  270W-L  means  low  current  gear; 
270W-H  means  high  current  gear  position;  the 
current division method required by other customers 
is  similar).  According  to  the  system  design 
requirements,  the  same  current  gear  position  is 
usually required in the same array during installation. 

If  the  customer  requires  PV  modules  to  be 
distinguished by color, the outer packaging box shall 
be marked accordingly, and the PV modules shall be 
marked  to  prevent  confusion  when  they  are  taken 
out of the packaging box and stacked. According to 
the  system  design  requirements,  the  color  of 
photovoltaic  modules  in  the  same  row  or  square 
array should be the same. 

6  Mechanical installation 

6.1  Installation conditions   

  Recommended  ambient  temperature:  -20°C  to 

+50°C;   

  Extreme  working  environment  temperature  of 

photovoltaic modules: -40°C to +85°C. 

 

Photovoltaic  modules  mechanical  load:

  Under 

standard  installation  conditions,  the  maximum 
test snow/wind load is 5400Pa/2400Pa, and the 
design load (considering a safety factor of 1.5) 
is 3600Pa/1600Pa.   

For  specific  installation  methods  and  mechanical 
load values of photovoltaic modules, please refer to 
Table  2  for  detailed  installation  instructions  for 
photovoltaic modules. 

Photovoltaic  modules  are  strictly  prohibited  to  be 
installed  and  used  in  excessive  environments  such 
as  hail,  snow,  hurricane,  sandstorm,  dust,  air 
pollution, and soot. It is strictly forbidden to install or 
use  photovoltaic  modules  in  an  environment  with 
strong corrosive substances (such as salt, salt spray, 
salt  water,  active  chemical  vapor,  acid  rain,  strong 
steam,  or  any  other  substances  that  will  corrode 
photovoltaic  modules  and  affect  the  safety  or 
performance of photovoltaic modules.). 

If  photovoltaic  modules  will  be  installed  in  special 
environments  such  as  high  temperature  and  high 
humidity environment, wet salt fog environment (C3 
and above areas specified in ISO 9223), water and 
breeding  farms,  etc.,  the  purchaser  or  user  must 
inform  8  Star  Energy  in  advance.  The  types  of 
photovoltaic  modules,  BOM,  and  quality  assurance 
issues shall be decided by the two parties through a 
joint agreement and understanding. 

If  the  above  precautions  are  not  followed,  the 
warranty will be invalid. 

6.2  Installation angle selection 

  The  tilt  angle  of  the  modules  is  measured 

between  the  surface  of  modules  and  a 
horizontal grounding face, as shown in figure 1. 
The modules generate maximum power output 
when it faces the sun directly. 

  In  the  northern  hemisphere,  modules  should 

typically  face  south,  and  in  the  southern 

Summary of Contents for Beam Series

Page 1: ...ilicon PV Modules Installation Manual Version 1 0 Released in November 2021 This guide describes how to install the Energizer Solar Beam crystalline silicon PV modules To prevent improper operation be...

Page 2: ...nergy ESS Ltd The Black Church St Mary s Place Dublin DO7 P4AX Ireland 1 Table of contents 1 Table of contents 2 2 Important notes 3 3 Laws and regulations 3 4 Safety measures 3 5 Handling and unpacki...

Page 3: ...ntrol of 8 Star Energy Proprietary Limited hereafter 8 Star Energy this manual does not have any warranty meaning whether express or implied 8 Star Energy will not be responsible for any form of injur...

Page 4: ...ive oil bone setting water thinner adhesive sheets that can generate oxime gas and potting glue only for connectors Such as KE200 CX 200 chemlok etc TBP plasticizer detergent etc to avoid chemical dam...

Page 5: ...voltaic module and the installation surface should be kept to prevent the installation surface from touching the junction box When installing on the roof comply with the fire protection requirements o...

Page 6: ...he original packaging box before installation Please protect the packaging from damage It is necessary to protect the safety of photovoltaic modules when unloading especially when hoisting roof projec...

Page 7: ...e system design requirements the color of photovoltaic modules in the same row or square array should be the same 6 Mechanical installation 6 1 Installation conditions Recommended ambient temperature...

Page 8: ...a third party testing organization with static mechanical analysis capabilities to meet the country region or corresponding international standards The photovoltaic module must be firmly fixed on the...

Page 9: ...gure 4 or Figure 5 The 400mm pitch mounting hole size is 7x10mm and 4 x M6 stainless steel bolts are required Figure 5 Secure each bolt to the frame with stainless steel washers one for each side of t...

Page 10: ...ar PV modules otherwise this may affect the modules operation or performance Be sure to avoid shadowing effects from the module clamps Weep holes on the module frame must not be closed or obscured by...

Page 11: ...stallation method Figure 2 3 Fig 4 Fig 7 Fig 8 Fig 5 ENSP60M1 ENSP60M1 BL 1755 1038 30 1765 1048 35 1755 1038 30 1765 1048 35 5400Pa 2400Pa 5400 2400Pa Installation scope 400 50mm 1800 1800Pa Installa...

Page 12: ...nditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions Accordingly the value of Isc marked on this module...

Page 13: ...ng coil and wire clip must be used to fix it on the bracket Avoid direct sunlight and water soaking cables Please keep the connector dry and clean and make sure that the nut of the connector is tighte...

Page 14: ...Note that the copper wire cannot be attached directly to the aluminum Put the bolt through the cut washer and then through the hole in the aluminum frame Add the spring washer and nut on the other si...

Page 15: ...t necessary to clean the PV module rain will have a self cleaning effect If there is a lot of dirt on the surface of the photovoltaic module which has seriously affected the power generation use water...

Reviews: