background image

Manual | EN

CP32xx-1600

Panel PC

12/7/2021 | Version: 1.0

Summary of Contents for CP32-1600 Series

Page 1: ...Manual EN CP32xx 1600 Panel PC 12 7 2021 Version 1 0 ...

Page 2: ......

Page 3: ...7 3 3 4 RS485 18 3 3 5 USB 19 3 4 Name plate 20 3 5 Connection cable 21 4 Commissioning 23 4 1 Transport and unpacking 24 4 2 Assembly 25 4 2 1 Dimensions 26 4 2 2 Installing the mounting arm tube 30 4 2 3 Installing a toolboard and handle 31 4 3 Connecting the Panel PC 32 4 3 1 Grounding the Panel PC 32 4 3 2 Connecting cables and power supply 34 4 4 Switching the Panel PC on and off 35 5 Beckhof...

Page 4: ...Table of contents CP32xx 1600 4 Version 1 0 9 Technical data 50 10 Appendix 51 10 1 Service and support 51 10 2 Approvals 52 ...

Page 5: ...es The configurations depicted may deviate from the standard Trademarks Beckhoff TwinCAT TwinCAT BSD TC BSD EtherCAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar are registered and licensed trademarks of Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the r...

Page 6: ...the safety notice may lead to minor injuries Warning of damage to property NOTE Disregarding the notice may lead to damage to property 2 2 Intended use The CP32xx 1600 Panel PC is designed for industrial use in machine and plant technology In addition to an integrated PC a TFT display with touch screen is mounted in an aluminum housing The Panel PC is mounted on the mounting arm The Panel PC has b...

Page 7: ...ng background operate the device Use by unauthorized persons can lead to damage to property and loss of data Protect the power supply cable with a fuse with a max rating of 16 A The fuse serves to protect the supply line in the event of a short circuit In case of fire extinguish the device with powder or nitrogen 2 4 Operator s obligation to exercise diligence The operator must ensure that the pro...

Page 8: ...etworks The latter should be connected to the corporate network or the Internet only if appropriate protective measures have been set up In addition the recommendations from Beckhoff regarding appropriate protective measures should be observed Further information regarding information security and industrial security can be found in our https www beckhoff com secguide Beckhoff products and solutio...

Page 9: ...imes high volume data handling other PC applications The Panel PC is available in the following five display sizes with corresponding resolutions in 5 4 and 16 9 formats 15 6 inch 1366 x 768 18 5 inch 1366 x 768 19 inch 1280 x 1024 21 5 inch 1920 x 1080 24 inch 1920 x 1080 The device has a multi finger touch screen and an aluminum housing with all round IP65 protection The housing surface is elect...

Page 10: ...splay and touch screen glass Operation of the Panel PC 2 Battery and storage media cover Access to battery and storage media 3 Extension plate with USB interface Additional USB interface with up to two further optional USB interfaces 4 Connection compartment Access to interfaces 5 Drill holes For mounting mechanical extensions 6 Fan cartridge Internal cooling of the Panel PC ...

Page 11: ... on the underside of the mounting arm adapter section A 2 Bend the cover slightly outwards so that you can push out the latching lugs 3 Slide the cover upwards off the mounting arm adapter section B ð You now have access to the connection compartment of the Panel PC section C 4 Push the cover back onto the mounting arm adapter from top to bottom until the latching lugs snap back into place A B C F...

Page 12: ..._ON 8 7 P S Power Status output minus is the negative pole of the supply voltage 9 NC not used 10 NC not used 11 NC not used 12 NC not used Table 3 Wiring with C9900 K275 K276 K277 Pin Wire Signal Description 1 1 8 BAT Negative pole of the battery pack 2 2 9 BAT Positive pole of the battery pack 3 3 NC not used 4 ye gn Protective earth 5 4 10 Negative pole Supply voltage 24 V 6 5 11 24 V Positive ...

Page 13: ... is selected automatically The cable is routed through the mounting arm adapter The RJ45 connection technology with twisted pair cables is used The maximum length of the cable connection is 100 m The Ethernet port is suitable for cycle times 1 ms and for distributed clock applications with EtherCAT The Intel i210 is used as controller 1 8 X102 Fig 5 CP32xx 1600_Ethernet interface pin numbering Tab...

Page 14: ...heral devices with USB connection The interface is located behind a screw cap It supplies 900 mA current and is electronically fused 1 2 3 4 5 6 9 78 Fig 6 CP32xx 1600_USB interface pin numbering Table 5 USB interface pin assignment Pin Connection Shield GND 1 Vbus 2 D 3 D 4 GND 5 StdA_SSRX 6 StdA_SSRX 7 GND_DRAIN 8 StdA_SSTX 9 StdA_SSTX ...

Page 15: ... USB 2 0 order identifier C9900 E190 USB 3 0 order identifier C9900 E304 CP32xx 1600 0030 Ethernet RJ45 order identifier FC9071 0001 requires PCIe module slot C9900 B519 2 x Ethernet RJ45 order identifier C9900 E282 requires PCIe module slot C9900 B519 Ethernet RJ45 order identifier C9900 E185 RS232 order identifier C9900 E186 RS422 order identifier C9900 E248 RS485 order identifier C9900 E261 USB...

Page 16: ...e T The required speed is selected automatically The RJ45 connection technology with twisted pair cables is used The maximum length of the cable connection is 100 m The Ethernet ports are suitable for cycle times 1 ms and for distributed clock applications in EtherCAT The Intel i210 is used as controller 1 8 Fig 7 CP32xx 1600_Optional Ethernet interfaces pin numbering Table 7 Ethernet interface pi...

Page 17: ...eration 7 RTS Signal out Request to Send 8 CTS Signal in Clear to Send 9 RI Signal in Ring Indicator 3 3 3 RS422 The optional RS422 serial interface includes an electrically isolated M12 socket for high speed serial data transmission The channel features overvoltage protection If an overvoltage occurs the channel is switched off 1 2 3 4 5 6 7 8 9 10 11 12 Fig 9 CP32xx 1600_RS422 interface pin numb...

Page 18: ...f an overvoltage occurs the channel is switched off 1 2 3 4 5 6 7 8 9 10 11 12 Fig 10 CP32xx 1600_RS485 interface pin numbering Table 11 RS485 pin assignment Pin Signal Type Description 1 2 TxD Data Out Transmit 485 3 RxD Data In Receive 485 4 5 GND Ground Ground 6 VCC VCC 5 V 7 TxD Data Out Transmit 485 8 RxD Data In Receive 485 9 On delivery the interface is configured as a half duplex endpoint ...

Page 19: ...ocated either in the connection compartment or in the extension plate It supplies 900 mA current and is electronically fused 1 2 3 4 5 6 7 8 9 Fig 11 CP32xx 1600_Optional USB interfaces pin numbering Table 13 USB interface pin assignment Pin Connection Shield GND 1 Vbus 2 D 3 D 4 GND 5 StdA_SSRX 6 StdA_SSRX 7 GND_DRAIN 8 StdA_SSTX 9 StdA_SSTX For USB 2 0 only pins 1 to 4 and the shield are relevan...

Page 20: ...name plate No Description 1 Model 2 Serial number BTN 3 Date of manufacture 4 Mainboard 5 CPU 6 Main memory 7 Storage media 8 Storage media 9 MAC addresses of the Ethernet interfaces 10 Power supply 24 VDC NEC class 2 11 Symbols Note here are the symbols applicable to the device such as CE EAC UKCA The approvals of your device can be found on the name plate and in chapter 10 2 Approvals 52 12 Addr...

Page 21: ...k cable Connection cable Network cable with IP65 plug C9900 K281 Network cable for CP32xx CP37xx and CP72xx length 3 m pre assembled Harting push pull Ethernet connector IP 65 second end RJ45 IP 20 C9900 K282 Network cable for CP32xx CP37xx and CP72xx length 5 m pre assembled Harting push pull Ethernet connector IP 65 second end RJ45 IP 20 C9900 K283 Network cable for CP32xx CP37xx and CP72xx leng...

Page 22: ...th 3 m pre assembled M12 plug connector IP 65 screw type 12 pin second end D Sub 9 connector C9900 K296 Serial interface cable RS232 for CP32xx CP37xx or CP72xx length 5 m pre assembled M12 plug connector IP 65 screw type 12 pin second end D Sub 9 connector C9900 K297 Serial interface cable RS232 for CP32xx CP37xx or CP72xx length 10 m pre assembled M12 plug connector IP 65 screw type 12 pin secon...

Page 23: ...ive film for Panel PCs and Control Panels with 21 5 inch display for fitting onto the glass pane 1 item C9900 T232 Adhesive protective film for Panel PCs and Control Panels with 24 inch display for fitting onto the glass pane 1 item Table 20 Ordering options Film fitted ex factory Ordering option Description C9900 T220 Adhesive protective film for Panel PCs and Control Panels with 15 6 inch displa...

Page 24: ...packaging can improve the vibration resistance during transport NOTE Hardware damage due to condensation Unfavorable weather conditions during transport can cause damage to the device Protect the device against moisture condensation during transport in cold weather or in case of ex treme temperature fluctuations Do not put the device into operation until it has slowly adjusted to the room temperat...

Page 25: ... option Order identifier Version C9900 M761 Rotatable and tiltable mounting arm adapter for CP32xx 16xxx clamping lever to lock the tilt Figure 13 shows the available mounting arm adapters It has a locking screw to prevent twisting and a clamping lever with which you can lock the tilt The mounting arm adapter can be rotated by 165 The adapter adapts the Panel PC with a 48 3 mm circular tube Fig 13...

Page 26: ...at a distance of 70 x 130 mm in front of the corresponding four M6 threaded holes on the rear side of the Panel PC section B A B Fig 15 CP32xx 1600_installing the mounting arm adapter 3 Tighten the four M6 screws with a tightening torque of 6 Nm 4 Replace the cover on the mounting arm adapter ð You have installed the mounting arm adapter on the Panel PC A strain relief plate is located inside the ...

Page 27: ...H 4x M6 6H 30 96 405 8 250 9 Fig 16 CP32xx 1600_dimensions 15 6 inch Fig 17 shows the dimensions of the 18 5 inch Panel PC 0 3 70 72 7 3x M5 6H 100 130 70 100 4x M6 6H 4x M6 6H 27 93 473 3 289 6 Fig 17 CP32xx 1600_dimensions 18 5 inch Fig 18 shows the dimensions of the 19 inch Panel PC ...

Page 28: ... 6H 4x M6 6H 29 95 433 2 356 Fig 18 CP32xx 1600_dimensions 19 inch Fig 19 shows the dimensions of the 21 5 inch Panel PC 100 130 70 100 4x M6 6H 4x M6 6H 0 3 70 72 7 3x M5 6H 28 94 537 2 321 7 Fig 19 CP32xx 1600_dimensions 21 5 inch Fig 20 shows the dimensions of the 24 inch Panel PC ...

Page 29: ...Commissioning CP32xx 1600 29 Version 1 0 0 3 70 72 7 3x M5 6H 100 130 100 70 4x M6 6H 4x M6 6H 28 94 592 2 352 2 Fig 20 CP32xx 1600_dimensions 24 inch ...

Page 30: ...ion Among other tools you need a hook wrench for the installation You can order this from your Beckhoff Sales using the following order identifier C9900 Z263 hook wrench size 58 62 for tying up the slotted nut of the C9900 M75x mounting arm adapter Fig 21 shows an example of the procedure with the mounting arm adapter facing downwards To install the mounting arm tube on the mounting arm adapter pr...

Page 31: ...minum mounted on the underside of a Control Panel or Panel PC CP3xxx can only be ordered together with the Control Panel or Panel PC C9900 M419 Toolboard for keyboard or tools mounted on the underside of a Control Panel or Panel PC CP3xxx without integrated IP 65 USB socket at the rear can only be ordered together with the Control Panel or Panel PC The handle 1 and the toolboard 2 are mounted on t...

Page 32: ... 6 4 1 b stipulates that one side of the circuit or a point of the energy source for this circuit must be connected to the protective conductor system Devices connected to the Panel PC with their own power supply must have the same potential for the PE and 0 V conductors as the Control Panel no potential difference 4 3 1 Grounding the Panel PC Potential differences are minimized and electrical cur...

Page 33: ... to material damage due to electromagnetic in terference Only use the device with functional earth Electromagnetic compatibility EMC of the Panel PC includes on the one hand not affecting other devices and equipment by electromagnetic interference and on the other hand not being disturbed by electrical or electromagnetic effects itself To do this the Panel PC must comply with certain protection re...

Page 34: ...data transmission lines Connecting the power supply Cables with a maximum cable cross section of 1 5 mm2 can be used for connecting the power supply For long supply lines use 1 5 mm2 cables to achieve a low voltage drop on the supply line There should be at least 22 V at the voltage connector of the Panel PC so that the PC remains switched on during voltage fluctuations Proceed as follows to conne...

Page 35: ...ificantly shortens the life of the battery Avoid switching off the power supply before shutting down the operating system Use the Beckhoff concept see below to shut down the operating system in a battery friendly manner When the system is switched off or disconnected from its own power supply the Panel PC is also switched off If you have a Panel PC with UPS and simply switch off the power supply t...

Page 36: ...lowing link https download beckhoff com download software Industrial_PC OS_Support Driver_DVD or you can contact Beckhoff Service service beckhoff com which will provide you with software and drivers The driver software comes with a detailed help function Call up the help files either directly from the configuration register by clicking the Help button or start the file under Start Programs Beckho...

Page 37: ...of using the Beckhoff Device Manager to remotely configure the Industrial PC via a web browser More detailed information is available in the Beckhoff Device Manager manual First start Beckhoff Device Manager When your Industrial PC is booted for the first time the Beckhoff Device Manager also starts automatically for the first time The Security Wizard opens This tells you that you should reset the...

Page 38: ...asswords are an important prerequisite for a secure system Beckhoff supplies the device images with standard user names and standard passwords for the operating system It is imperative that you change these Controllers are shipped without a password in the UEFI BIOS setup Beckhoff recommends assigning a password here as well Please note the following Passwords should be unique for each user and se...

Page 39: ...thunderstorm can lead to electric shock Never disconnect the cables of the Panel PC during a thunderstorm Before removing the Panel PC follow the steps below 1 Shut down the Panel PC 2 Gain access to the connection compartment of the PC see chapter 3 2 Interface description 11 3 Disconnect the Panel PC from the power supply see below 4 Disconnect the data transfer cables between the Panel PC and t...

Page 40: ...r with a hook wrench size 58 62 in counterclockwise direction section B The ordering option for the hook wrench can be found in chapter 4 2 2 Mounting arm tube installation 30 3 Pull the mounting arm tube out of the mounting arm adapter section C 4 Tighten the Allen locking screw again with a torque of 3 Nm ð You have removed the mounting arm tube from the mounting arm adapter 1 C B A Fig 27 CP32x...

Page 41: ...ssioning CP32xx 1600 41 Version 1 0 A B Fig 28 CP32xx 1600_removing the mounting arm adapter Disposal of the Panel PC When disposing of the Panel PC be sure to observe the national electronic waste regulations ...

Page 42: ...IP65 Never use compressed air to clean the PC Maintain an ambient temperature range of 0 C to 45 C Cleaning agents In order to avoid damage to the front of the Panel PC during cleaning you must use suitable cleaning agents Examples include benzine spirit acetone Glass cleaner Avoid the following cleaning agents Detergents with scouring or abrasive components Metal cleaning objects such as razor bl...

Page 43: ...nly use spare parts that you have ordered from Beckhoff Service Beckhoff Panel PCs are manufactured from components of the highest quality and robustness They are selected and tested for best interoperability long term availability and reliable function under the specified environmental conditions Nevertheless some components of the Panel PC may be subject to a limited service life if they are ope...

Page 44: ...vices there is a risk of damage due to ESD electrostatic discharge which can impair the function or destroy the device Protect the Panel PC and create an ESD protected environment in which existing electrostatic charges are safely discharged to ground and charging is prevented An ESD protected environment can best be created by setting up ESD protection zones The following measures serve this purp...

Page 45: ...olarity is correct NOTE Battery damage Incorrect handling of the motherboard battery can damage it Do not recharge the battery Do not throw the battery on the fire Do not open the battery Protect the battery against direct sunlight and moisture NOTE Motherboard failure Scratches on the motherboard may cause the motherboard to fail Be very careful when replacing the battery and be sure to avoid scr...

Page 46: ...nose pliers 2 Insert the new battery into the PC by hand Pay attention to the correct polarity The negative pole of the battery must face the display see Fig 32 Fig 32 CP32xx 1600_replacing the battery To dispose of the battery remove it tape off the poles and put it in the battery disposal ...

Page 47: ...he backup copy of your operating system You can then keep the flash drive as a backup copy For this purpose the BST USB flash drives with SLC flash are designed for a particularly long data preservation For more information on the function of the BST please refer to the corresponding manual If your storage medium is defective and there is no backup Beckhoff Service can provide you with a fresh Win...

Page 48: ...C is running Insert the new fan cartridge immediately after removing the old one If you look at the device from the back the fan cartridge is located in the right side of the PC To replace the fan cartridge follow the steps below as shown in Figure 34 1 Loosen the four M3x6 screws of the fan cartridge section A 2 Remove the fan cartridge section B Fig 34 CP32xx 1600_exchange fan cartridge 3 Insert...

Page 49: ...k properly The cause of the error is the software or plant parts outside of the Panel PC Call the machine or software manufacturer The Panel PC only works partially or only temporarily e g dark image or none at all Defective backlight in the display Components defective in the Panel PC Call Beckhoff Service Call Beckhoff Service Malfunction of the touch screen Poor or missing functional earth of t...

Page 50: ...nusoidal vibration EN 60068 2 6 10 58 Hz 0 035 mm 58 500 Hz 0 5 G 5 m s2 Shock resistance shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC interference immunity conforms to EN 61000 6 2 EMC interference emission conforms to EN 61000 6 4 Permissible ambient temperature Operation 0 C to 45 C Transport storage 20 C to 65 C Permissible relative air humidity Maximum 95 no condensation Transport and s...

Page 51: ...which can be found on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services World wide support design programming and commissioning of complex automation systems extensive training program for Beckhoff system components Hotline 49 0 5246 963 157 Fax 49...

Page 52: ...n against adverse interference if the device is used in a commercial environment This device generates uses and may emit radio frequency energy and may cause adverse interference with radio communications if it is not installed and used in accordance with the operating instructions If this device is used in a residential area it is likely to cause adverse interference in which case the user must t...

Page 53: ...Fig 15 CP32xx 1600_installing the mounting arm adapter 26 Fig 16 CP32xx 1600_dimensions 15 6 inch 27 Fig 17 CP32xx 1600_dimensions 18 5 inch 27 Fig 18 CP32xx 1600_dimensions 19 inch 28 Fig 19 CP32xx 1600_dimensions 21 5 inch 28 Fig 20 CP32xx 1600_dimensions 24 inch 29 Fig 21 CP32xx 1600_installing the mounting arm tube 30 Fig 22 CP32xx 1600_handle and tray 31 Fig 23 CP32xx 1600_grounding bolt for ...

Page 54: ...onfiguration 18 Table 11 RS485 pin assignment 18 Table 12 RS485 standard configuration 18 Table 13 USB interface pin assignment 19 Table 14 Legend for CP32xx 1600 name plate 20 Table 15 Power supply cable 21 Table 16 Network cable 21 Table 17 USB cables 21 Table 18 Serial interface cable RS232 22 Table 19 Ordering options Film individual 23 Table 20 Ordering options Film fitted ex factory 23 Table...

Page 55: ......

Page 56: ...Beckhoff Automation GmbH Co KG Hülshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com cp32xx 1600 ...

Reviews: