Summary of Contents for ECO 250esm

Page 1: ...mage severe personal injury or death NOTICE ENERGIE reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature CONSUMER INF...

Page 2: ...surely meet all your expectations and provide many years of comfort with maximum savings We have taken on a permanent commitment to conceive innovative and efficient products so that the rational use...

Page 3: ...ncludes all related control information It is important that these manual all other documents included with this system and additional publications Installation should be made in accordance with the r...

Page 4: ...9 4 2 REQUIRED CLEARANCES 10 4 3 THERMAL EXPANSION 11 4 4 WATER CONNECTIONS 11 4 5 TP RELIEF VALVE 12 4 6 ELECTRICAL CONNECTIONS 12 5 RUNNING PRINCIPLE 14 6 TECHNICAL FEATURES 15 7 MAIN COMPONENTS GEN...

Page 5: ...ION 30 10 SYSTEM START UP 30 11 START UP WHAT TO EXPECT 31 12 CONTROLS OVERVIEW 31 13 DISPLAY OVERVIEW 33 14 SETTING THE WATER TEMPERATURE 34 15 ADJUSTING THE FUNCTION MODE 34 16 ABOUT THE USER INTERF...

Page 6: ...ter heater as this may save time and cost Perform steps in the order given Should you have problems understanding the instructions in this manual or any questions STOP and get help from a qualified se...

Page 7: ...ower thermostat setting to prevent contact with HOT water Aproximate time temperature relationships in sacalds Teperature Time to produce a serious burn 120 F 49 C More than 5 minutes 125 F 52 C 1 to...

Page 8: ...his or any other water heater Open doors and windows for ventilation if such flammables must be stored near the water heater NOTE Flammable vapors may be drawn by air currents from surrounding areas t...

Page 9: ...location chosen for the water heater must take the following into consideration LOCAL INSTALLATION REGULATIONS This water heater must be installed in accordance with these instructions local codes uti...

Page 10: ...s or removers Because of natural air movement in a room or other enclosed space flammable vapors can be carried from where flammable liqu ids are being used or stored The operation of the control syst...

Page 11: ...an expansion tank in the cold water line between the water heater and the check valve The expansion tank is designed with an air cushion built in that compresses as the system pressure increases there...

Page 12: ...the outlet of the valve and must pitch downward from the valve to allow complete drainage by gravity of the relief valve and discharge line The end of the discharge line should not be threaded or conc...

Page 13: ...state codes follow NFPA 70 the National Electrical Code current edition Water heater and electrical supply are properly grounded Wiring enclosed in approved conduit if required by local codes Dedicat...

Page 14: ...agents mentioned ensures the klea ecological cooling fluid will evaporate inside the solar panel The absence of glass in the panel allows for an increased thermal exchange by convection After circula...

Page 15: ...rofobic Anodized Aluminium Dimensions L x A x e mm ft 2000 x 800 x 20 6 56x 2 63 x 0 065 Weight Kg lb 8 17 6 Maximum working pressure bar psi 10 145 Test pressure bar psi 12 174 Maximum exposure tempe...

Page 16: ...1 Thermodynamic solar panel 2 L shaped fastenings for attachment of aluminium panel 3 Set of bolts female washer and bushing 6x or 8x 4 Refrigerant copper pipes 5 Water storage heater 6 Thermodynamic...

Page 17: ...nections side Left Panel Right Panel The panel connections are Flare SAE threaded type 3 8 Flare male SAE Aspiration upper part 1 4 Flare male SAE Liquid lower part The solar panel has standard dimens...

Page 18: ...ater outlet and return inlet It also supplied with a magnesium anode on the top There is in the central part of the storage water heater a flanged opening with a safety thermostat temperature probe an...

Page 19: ...that contains two of the main parts of the system compressor and expansion valve The lateral section of the group has two valves of 2 and 3 ways conceived for connecting to the panel 3 8 Aspiration 1...

Page 20: ...ECO Installation Instructions and Use Care Guide 20...

Page 21: ...quipment must be carried out by a qualified technician 8 6 PROTECTION AGAINST CORROSION The storage water heater in this equipment can be of two types Stainless steel or Enamelled Besides being resist...

Page 22: ...r inlet and outlet A and B before attaching the piping D as demonstrated in the following sequence 9 INSTALLATION Assembly sequence Solar panel Storage water heater Thermodynamic Group Cooling connect...

Page 23: ...holes made in the panel Attachment of L shaped fastenings Attachment of L shaped fastenings and panel 1 Aluminium L shaped fastening 5 Bolt M6x20 2 Plastic Bushing 6 Nut M6 3 Self thread bolt M6x40 7...

Page 24: ...The storage water heater must never be kept outside and avoid exposure to sunlight Make sure the support surface is enough to accommodate the weight of the storage water heater filled with water Min 7...

Page 25: ...g fluid couplings must be done by a qualified technician with a professional certificate of qualifications for this purpose Failure to follow this warning could result in property damage personal inju...

Page 26: ...moving the protective caps from the extremities b Place the extremities of the pipe upside down cut the appropriate size of pipe and sand the rough edge c Remove the females from the couplings in the...

Page 27: ...gs between the group and the storage water heater Procedure for making the refrigeration couplings a Remove the protection caps from the one shot valves on the pipes of the condenser and thermodynamic...

Page 28: ...le coupling with your hand giving it a few turns and secure with wrench applying the torque as before NOTE Every coupling must be insulated 9 8 NITROGEN LOAD a After finishing the couplings make sure...

Page 29: ...letely shut until there is a vacuum of 50 Pa 0 5mbar f Once the vacuum procedure is over shut the vacuum pump valves The vacuum pressure gauge should indicate the same reading after the pump has stopp...

Page 30: ...he 3 way valve f Switch on the compressor again and check how it runs 9 11 CHECKING GOOD RUNNING CONDITION To check whether your equipment is running correctly start it and wait at least 20 30 minutes...

Page 31: ...r for user 30 minutes Heater element turns off and compressor turns back on Uses efficient heat pump for majority of heating 12 CONTROLS OVERVIEW 1 Display 2 UP button Use up arrow to increase value o...

Page 32: ...press and hold the ENTER key for 3 seconds 3 Diagnostic Function This function allows service technicians or users to view water heater parameters To open the Diagnostic Function unlock the control On...

Page 33: ...Lock Icon This icon lights when the key pad is locked and will shut off when the key pad is unlocked 5 Alarm Icon The alarm icon will flash and an alarm will sound when the water heater is in error an...

Page 34: ...le Contact a licensed plumber or the local plumbing authority for further information To Adjust the Temperature first unlock the key pad by pressing and holding the ENTER key for 3 seconds Next press...

Page 35: ...R key or wait ten seconds for the Auto Confirm Function to automatically accept the number of days For example if you will be gone 14 days select 14 with the key pad The water heater will then automat...

Page 36: ...al block of the element or on the water heater data plate IMPORTANT Before replacing any element confirm that you have the correct replacement element wattage This water heater has a folded 1500 watt...

Page 37: ...perature and operating mode 19 MAINTENANCE PROCEDURES 19 1 MAGNESIUM ANODE The anode must be removed in order to check it state If the magnesium anode is letting water pass it will be necessary change...

Page 38: ...ECO Installation Instructions and Use Care Guide 38 20 WIRING DIAGRAM...

Page 39: ...ll faucets are closed Electric service to your home may be interrupted Contact the local electric utility Improper wiring Do not attempt to repair wiring Call for service Manual reset limit SP A tripp...

Page 40: ...ump error 1 Powering the water heater off and restart 2 Press ENTER and UP to enter Diagnostic Function and check error code history E8 Water temperature too high T2 greater than 165 F 1 Check if sens...

Page 41: ...____ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _________...

Page 42: ...O Installation Instructions and Use Care Guide 42 Zona Industrial de La ndos Lote 48 Energie est lda 4570 311 La ndos P voa de Varzim Portugal Tel 351 252 600 230 Fax 351 252 600 239 Web www energie p...