![Energie ECO 250esm Installation Instructions And Use & Care Manual Download Page 37](http://html1.mh-extra.com/html/energie/eco-250esm/eco-250esm_installation-instructions-and-use-and-care-manual_2409981037.webp)
ECO
Installation Instructions and Use & Care Guide
37
8. Make sure the replacement element has the correct voltage and wattage rating by matching it to the
rating plate on the water heater. Position the new gasket on the element and insert it into the water heater
tank.
NOTE: Apply a light coat of hand dishwashing soap and water to the gasket. Tighten the element by turning
it clockwise until secure.
9. Close the drain valve and open the nearest hot water faucet. Then open the cold water shut off valveand
allow the tank to fill completely with water. To purge the lines of any excess air and sediment, keep the hot
water faucet open for 3 minutes after a constant flow of water is obtained.
10. Check for leaks around the element.
11. Reconnect the electrical wires to the element.
12. Replace the protective cover removed earlier. Make sure the cover is securely engaged on the
attachment point(s).
15. Reconnect electrical power to the water heater at the circuit breaker/fuse box.
16. Press the power button to turn the water heater on. Set the desired water temperature and operating
mode.
19.
MAINTENANCE PROCEDURES
19.1.
MAGNESIUM ANODE
The anode must be removed in order to check it state.
If the magnesium anode is letting water pass it will be necessary change it. The period between changing the
anode is always dependent of the water quality in each location. In areas with raised concentrations of
soluble solids, the anode needs to be changed with less regularity, whereas in situations with low
concentration, the anode needs to be changed with greater regularity. Therefore the magnesium anode
state shall be checked at least one time per year.
19.2.
PRESSURE REDUCING VALVE FILTER
The following procedure shall be done for periodic (maximum once every two years) cleaning of the pressure
reduction valve filter:
1.
Close the passage of water from the network.
2.
Turn in an anti-clockwise direction after relieving the spring’s tension.
3.
Draw back the lever/handle.
4.
Remove the filter and clean it.
19.3.
TEMPERATURE AND PRESSURE RELIEF VALVE
At least once a year, lift and release the lever handle on the temperature and pressure relief valve, located
on the back left side of the water heater, to make sure the valve operates freely. Allow several gallons of
water to flush through the discharge line to an open drain.