background image

16

EGM-PWM ENERGY METER

All brands and logos are registered trademarks of their respective owners

Note:

 The scale of the vertical axis changes automatically once you

browse or zoom the chart. The scale will be chosen in such a way that all
the values within the displayed time period fit onto the screen.

Some extra tools are placed under the chart:

From  the

Displayed  value

  list  box  you  can  choose the value

which you wish to display in the graph area...

The displayed chart normally shows the average values  of  the

chosen  parameter.  You  can  determine  the data  point density  with  the

Graph details level

 slider. With this slider you actually change the number

of  points  within  the  chosen  time  interval  for  the  averaging.  Fewer  points

mean less details  and a smoother  chart.  More  points mean more details

and a more precise chart.

- The Sum tool is used to calculate energy statistics within a

selected time period. Push the Σ- button to activate this feature and then

select a time period on the chart area by dragging and dropping with the

left  mouse  button.  Doing  so  you will select the period as  shown  on  the

Figure # 8 below. The chosen period will be selected on the chart and the

start  and  finish values  of  the  interval  will  be shown in  the  corresponding

fields inside

Statistics for the period

 box. The calculated average value will

be shown in the

Mean value

field.

Tip:

 You can calculate the total energy consumption within a certain

period using this function in Real power chart.

Note:

 you can also adjust the

Start

 and

Finish

 fields manually.

Summary of Contents for EGM-PWM

Page 1: ...USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF EGM PWM ENERGY METER...

Page 2: ...2 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Energy Meter Energiemessger t Energiemeter Compteur d nergie...

Page 3: ...me use and advanced readings business scientific use Specifications Input 220 240 V AC 50 60 Hz Load max 10 A Power consumption max 1 2W USB 1 1 or 2 0 compatible interface Computer measurements volta...

Page 4: ...EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners 1 Indicators and controls of the EGM PW Figure 1 Socket Load indicator Day Night mode indicator USB socke...

Page 5: ...ator Load is lit up it means that the connected equipment is consuming energy 2 Hardware requirements A free USB port Windows XP 2000 Vista Windows 7 Windows 8 3 Package contents EGM PWM User manual U...

Page 6: ...the EGM PWM see Figure 1 above to your computer with the supplied USB cable 4 Plug any device into the Socket see Figure 1 above of the EGM PWM and you are ready to measure its energy consumption 5 So...

Page 7: ...the software keeps downloading the power readings from the EGM PWM into a database In the offline mode the EGM PWM will only save Energy consumption data kWh which will be logged into the database wh...

Page 8: ...PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Figure 2 Push the Device settings button bottom right here to set the device specific options see Figure 3 b...

Page 9: ...to change the name of your device in the Name field and the data downloading frequency in the Measurement reading period field from 2 to 10 seconds To delete all previous recorded data just push the C...

Page 10: ...r a minimized or maximized mode The minimized Power Meter window is shown in Figure 4 below This window is useful for monitoring selected measured values It displays A single measured value e g money...

Page 11: ...1 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Push Maximize button in this window to open the full size Power Meter window see Figure 5 below Figure...

Page 12: ...explain the physical meaning of these values For most consumers the energy and its cost are the most interesting The Energy E value shows the accumulated energy consumption in watt hours since a certa...

Page 13: ...rks of their respective owners Figure 6 Choose the rate per kWh and currency If you have different rates for peak hours and off peak hours just check the box Use Day Night modes You will then be able...

Page 14: ...R Fq Irms Vrms and Cost are continuously logged into the database These readings can be used to build time charts To display the charts just click on the desired value in the Main Power Meter window s...

Page 15: ...ENERGY METER All brands and logos are registered trademarks of their respective owners Figure 7 The horizontal axis represents the date time and the vertical axis represents the values of the chosen...

Page 16: ...thin the chosen time interval for the averaging Fewer points mean less details and a smoother chart More points mean more details and a more precise chart The Sum tool is used to calculate energy stat...

Page 17: ...17 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Figure 8...

Page 18: ...button and then click with the left mouse button to adjust the scale to the desired level When you select the home tool the chart displays every record from the whole period where the selected paramet...

Page 19: ...apter 7 above or run a user specified application To set the parameters for such events see Figure 10 below just push the Events button in the Power Manager window see Figure 2 above Figure 10 To defi...

Page 20: ...cation or program you can select the path to this application in the Path field It is possible to give the event a practical name in the Name field Select the Use growth checkbox if you are interested...

Page 21: ...21 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners...

Page 22: ...22 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners...

Page 23: ...er ten Richtlijnen m b t afvalverwerking Batterijen en accu s dienen als klein chemisch afval afgeleverd te worden bij toegewezen afvalverzamelpunten zie www afvalgids nl U dient ervoor te zorgen dat...

Page 24: ...redit note amount will always be calculated on the basis of the current market value of the defective products Die Garantie betr gt 24 Monate ab Verkaufsdatum an den Endverbraucher Das Kaufdatum und d...

Page 25: ...n de garantie doit num rer clairement la date d achat et le type d appareil Conservez le re u d achat pendant toute la dur e de la garantie car elle est n cessaire pour toute r clamation Au cours de l...

Page 26: ..._______________ 20____ _________________________________ ________________________________________________ _____________ _____________ 1 2 3 4 ____________________ __________________________ __________...