background image

23

EGM-PWM ENERGY METER

All brands and logos are registered trademarks of their respective owners

Waste disposal:

      Do  not deposit  this  equipment  with  the

household waste. Improper disposal can harm

both  the  environment  and  human  health.  For

Information about waste collection facilities for

used electrical and electronic devices, please

contact  your  city  council  or  an  authorized

company  for  the  disposal  of  electrical  and

electronic equipment.

Entsorgungshinweise:

       Werfen  Sie  dieses  Gerät  nicht  in  den

Hausmüll.  Unsachgemäße  Entsorgung  kann

sowohl der Umwelt als auch der menschlichen

Gesundheit  schaden.  Informationen

zu

Sammelstellen  für  Altgeräte  erhalten  Sie  bei

Ihrer  Stadtverwaltung  oder  einer autorisierten

Stelle  für  die  Entsorgung  von  Elektro-und

Elektronikgeräten.

Richtlijnen m.b.t. afvalverwerking

      Batterijen  en  accu’s  dienen  als  klein-

chemisch  afval afgeleverd  te  worden  bij

toegewezen 

afvalverzamelpunten 

(zie

www.afvalgids.nl).  U  dient  ervoor  te  zorgen

dat de batterijen/accu’s leeg zijn en dus geen

stroom  meer  kunnen  leveren.  Let  op,  de

batterijen/accu’s 

dienen 

onbeschadigd

ingeleverd te worden.

Gooi dit product niet weg in uw vuilnisbak. Dit

kan  zowel  het  milieu  als  de  menselijke

gezondheid  schade  toebrengen.  Informatie

over  het  inleveren  van  dit  product  kunt  u

inwinnen bij uw gemeentelijke vuilnisdienst of

andere geautoriseerde instelling in uw buurt.

Traitement des déchets:

      Ne jetez pas cet appareil dans les déchets

domestiques.  Un  traitement  inapproprié  peut

être  dommageable  à  l'environnement  et  à  la

santé humain.

Vous trouvez des informations sur les centres

de  rassemblement  des  appareils  vieux  chez

l'administration municipale ou

chez un centre autorisé pour le traitement des

appareils électriques ou électroniques.

Summary of Contents for EGM-PWM

Page 1: ...USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF EGM PWM ENERGY METER...

Page 2: ...2 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Energy Meter Energiemessger t Energiemeter Compteur d nergie...

Page 3: ...me use and advanced readings business scientific use Specifications Input 220 240 V AC 50 60 Hz Load max 10 A Power consumption max 1 2W USB 1 1 or 2 0 compatible interface Computer measurements volta...

Page 4: ...EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners 1 Indicators and controls of the EGM PW Figure 1 Socket Load indicator Day Night mode indicator USB socke...

Page 5: ...ator Load is lit up it means that the connected equipment is consuming energy 2 Hardware requirements A free USB port Windows XP 2000 Vista Windows 7 Windows 8 3 Package contents EGM PWM User manual U...

Page 6: ...the EGM PWM see Figure 1 above to your computer with the supplied USB cable 4 Plug any device into the Socket see Figure 1 above of the EGM PWM and you are ready to measure its energy consumption 5 So...

Page 7: ...the software keeps downloading the power readings from the EGM PWM into a database In the offline mode the EGM PWM will only save Energy consumption data kWh which will be logged into the database wh...

Page 8: ...PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Figure 2 Push the Device settings button bottom right here to set the device specific options see Figure 3 b...

Page 9: ...to change the name of your device in the Name field and the data downloading frequency in the Measurement reading period field from 2 to 10 seconds To delete all previous recorded data just push the C...

Page 10: ...r a minimized or maximized mode The minimized Power Meter window is shown in Figure 4 below This window is useful for monitoring selected measured values It displays A single measured value e g money...

Page 11: ...1 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Push Maximize button in this window to open the full size Power Meter window see Figure 5 below Figure...

Page 12: ...explain the physical meaning of these values For most consumers the energy and its cost are the most interesting The Energy E value shows the accumulated energy consumption in watt hours since a certa...

Page 13: ...rks of their respective owners Figure 6 Choose the rate per kWh and currency If you have different rates for peak hours and off peak hours just check the box Use Day Night modes You will then be able...

Page 14: ...R Fq Irms Vrms and Cost are continuously logged into the database These readings can be used to build time charts To display the charts just click on the desired value in the Main Power Meter window s...

Page 15: ...ENERGY METER All brands and logos are registered trademarks of their respective owners Figure 7 The horizontal axis represents the date time and the vertical axis represents the values of the chosen...

Page 16: ...thin the chosen time interval for the averaging Fewer points mean less details and a smoother chart More points mean more details and a more precise chart The Sum tool is used to calculate energy stat...

Page 17: ...17 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners Figure 8...

Page 18: ...button and then click with the left mouse button to adjust the scale to the desired level When you select the home tool the chart displays every record from the whole period where the selected paramet...

Page 19: ...apter 7 above or run a user specified application To set the parameters for such events see Figure 10 below just push the Events button in the Power Manager window see Figure 2 above Figure 10 To defi...

Page 20: ...cation or program you can select the path to this application in the Path field It is possible to give the event a practical name in the Name field Select the Use growth checkbox if you are interested...

Page 21: ...21 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners...

Page 22: ...22 EGM PWM ENERGY METER All brands and logos are registered trademarks of their respective owners...

Page 23: ...er ten Richtlijnen m b t afvalverwerking Batterijen en accu s dienen als klein chemisch afval afgeleverd te worden bij toegewezen afvalverzamelpunten zie www afvalgids nl U dient ervoor te zorgen dat...

Page 24: ...redit note amount will always be calculated on the basis of the current market value of the defective products Die Garantie betr gt 24 Monate ab Verkaufsdatum an den Endverbraucher Das Kaufdatum und d...

Page 25: ...n de garantie doit num rer clairement la date d achat et le type d appareil Conservez le re u d achat pendant toute la dur e de la garantie car elle est n cessaire pour toute r clamation Au cours de l...

Page 26: ..._______________ 20____ _________________________________ ________________________________________________ _____________ _____________ 1 2 3 4 ____________________ __________________________ __________...

Reviews: