background image

User Manual 

 

 

Page 2

 

1. INTRODUCTION 

 
The DX Box is designed to connect two 
load/unload air compressors to a system 
management unit, using a 2-wire RS485 data 
cable up to 500m (1650ft) in length. 
 
The DX Box is designed specifically to ‘group’ 
two compressors together as a single 
coherent unit. The system management unit 
will detect and manipulate the two 
compressors as a single multiple step or 
variable output compressor unit. 
 
The DX Box is able to manipulate two identical 
capacity compressors to form a single ‘group’ 
that will act in an identical manner as a 3-step 
compressor. The DX Box is also able to 
manipulate two differential capacity 
compressors providing demand matched 
control and sequence to form a single ‘group’ 
that will act in an identical manner as a 
variable stepping output, compressor. 
 
This functionality provides the ability to: 

a)  Group two adjacent air compressors 

together as a single coherent unit. 

b)  Combine two similar capacity 

compressors together to form a three-
step variable output group acting as a 
single coherent variable output unit. 

c)  Take advantage of a small or minimal 

capacity compressor, grouped 
together with a medium or higher 
capacity compressor, to form a high 
capacity, variable output, group acting 
as a single variable output ‘top-up’ 
compressor. 

d)  Exceed the maximum compressor 

control capability of a system 
management unit by combining 
compressors together as one. 

 
Two single pressure switch control type air 
compressors can be connected to the DX Box 
using a 6-wire cable and a compressor 
interface PCB (i-PCB). The ‘i-PCB’ 
connections are identical to an system 
management unit. 
 
The DX Box also provides optional ‘local 
pressure sensor’ connections. The 
compressor delivery pressures, local system 
pressure and air treatment differential 
pressures can be displayed. The monitored 
local pressure is available on the system 
network and can be utilised by an system 
management unit for advanced pressure 
related functions. 
 

 
 
Any number of DX Boxes can be connected to 
an system management unit as long as the 
total number of single compressors and/or 
groups does not exceed the total number of 
compressors for the system management unit 
model. 
 

1.1 Management System Connectivity 

 

1

2

#1

DX Box

3

#2

 

 
The DX Box connects to an ystem 
management unit using an industrial two wire 
RS485 data network (Multi485). 
 

1.2 Basic Function 

 
The DX Box is a ‘Duel unit eXtension’ to a 
system management unit providing the ability 
to group two individual air compressors 
together in to one duel ‘group’ acting as a 
single coherent unit. 
 
The DX Box provides additional ‘i-PCB’ 
connectivity. 
 
The DX Box can also be used to provide ‘i-
PCB’ connectivity at a remote location beyond 
the maximum distance specification of direct 
system management unit connection. 
 

1.3 Operation 

 
2.3.1 Timer Rotation Mode (Tr) 
 

#1

#2

50%

50% = 100%

1

A B

2

B A

A

B

 

 
Timer Rotation should be used when the two 
compressors have the same (50:50), or very 
similar, output capacity. The DX Box will 
assign one compressor as ‘Duty’ and the other 
as ‘Standby’. The duty compressor will always 
be loaded first and the standby used as and 
when required to meet demand. The duty and 
standby assignment will be changed at every 
‘Interval Time’ (adjustable). 
 

Summary of Contents for metacentre DX Box

Page 1: ...MANY0739A GB Metacentre DX Box User Manual TM DX Box bar...

Page 2: ...tatus Symbols 2 4 Indications 2 5 Compressor Identification 2 6 Operation 2 7 Power Failure Auto Restart 2 8 Failure Modes 2 9 Compressor Fault 2 10 DX Box Fault 2 11 Pressure Sensor Fault 3 0 Parts L...

Page 3: ...6 wire cable and a compressor interface PCB i PCB The i PCB connections are identical to an system management unit The DX Box also provides optional local pressure sensor connections The compressor de...

Page 4: ...change from time to time dependant on the set sequencing mode of the management unit In Top Up mode the DX Box will allow variable capacity control as described above dependant on demand In Base Load...

Page 5: ...esented on the system management unit as compressor number 03 The status of the compressor will also be show using the Run and Load symbols If the Delivery pressure sensor option for a compressor has...

Page 6: ...Local mode 2 5 Power Failure Auto Restart The DX Box will always automatically start when power is re applied after a power supply disruption or failure 2 6 Failure Modes If communications with the sy...

Page 7: ...ontroller inputs and outputs E 0135 BAR System Pressure Sensor Fault If one of these fault conditions occur the DX Box will switch off The Run Indicator 9 will also switch off and the Fault Indicator...

Page 8: ...tem Part No Description 5 Y04CM59 00 Unit i PCB Optional Accessories Item Part No Description 6 Y04CM29 00 Sensor Pressure 4 20mA 0 16 0bar 7 Y01ENER35 00 Module Relay 24Vac 4 0 Technical Data Dimensi...

Page 9: ...3 C024 C025 C032 C030 C031 4 20mA Pressure 1 4 20mA SystemPress Ai3 VDC notused Aux Fault 2 Aux Output V1 8 10 12 X02 11 9 7 V2 C028 C029 C026 C027 X04 notused C015 C025 C024 10k 10k C016 C023 C013 C0...

Page 10: ...115V 24Vac 1 isolated 24Vac 2 earthed E E L N N L E BLUE BROWN RED GREEN VIOLET WHITE ORANGE BLACK FH1 FH2 FH3 FH4 FH5 1 VOLTAGE SELECT 2 3 4 X04 2 1 2 X03 X02 X01 T3 15A T1 6A T1 6A T1 0A T1 0A 1 2...

Reviews: